  • Amplifier Alignment Unit TS-92/AP is a class

A special test equipment used in aligning the amplifier stages of radar jamming transmitters. It can be used with Transmitting Equipment AN~APT-1, Radio Set AN~ARQ-8. Using the TS-92/AP the amplifier of the transmitter may be adjusted to give optimum performance at any band width between0.5to 7 mc. for any carrier frequency in the range from 15-250 mc. This simple device is intended for use in the field where more elaborate equipment, such as oscilloscope and sweep oscillator, is not available. It consists essentially of a radio receiver designed in such a way that the two peaks in the amplifier response curve may be maximized to give optimum adjustment of the amplifier. Power is obtained from a-115volt 60-2600 c.p.s., a.c. power source. A one-tenth volt input gives full scale meter indication. Army Supply Program requirements as of 10 November 1944 were 660 equipments for the calendar year 1944 and 1,667 for 1945.