Contents
Overview
Decibel Meter ME-22/PCM is a portable, amplifier-rectifier type output power measuring unit used in testing wire and wire-radio communication circuits.
Relationship to Similar Equipment
This equipment, with the signal generator SG-15/PCM, is part of Telephone Test Set TS-140/PCM.
Technical Description
- Power Requirements
- 50 w, 115 or 230 v ±10%, 50 to 70 cy, 1 phase ac
- Frequency Range
- 200 to 35,000 cy
- Impedance
- 600 ohms; 8,000 ohms
- Meter Range
- -45 to +25 dbm
- Accuracy
- ± .5 db
- Major Unit
- ME-22/PMC 7" x 19" x 10 7/8"'; 37 lbs
Tubes, Crystals, Transistors
- 1 - OC3
- 1 - 5Y3GT
- 1 - 6H6
- 1 - 6L6GAY
- 3 - 6SJ7
- 1 - 6SQ7
Reference Data and Literature
- TM 11-2096
- MIL-T-12643