Difference between revisions of "SG-15~PCM"
Jump to navigation
Jump to search
(Created page with "==Overview== ==Relationship to Similar Equipment== This equipment, with the signal generator ME-22/PCM, is part of Telephone Test Set TS-140/PCM. ==Technica...") |
|||
(3 intermediate revisions by the same user not shown) | |||
Line 1: | Line 1: | ||
==Overview== | ==Overview== | ||
+ | The range of frequency is generated in only one band, from 20 to 35000 Hz.<br/> | ||
+ | The method of generation is different from other signal generators:<br/> | ||
+ | the variable frequency oscillator operates from 100 to 135 Khz, its output is beated with a fixed oscillator of 100 Khz in a mixer<br/> | ||
+ | the output of which, filtered and amplified, is the signal at the output connector.<br/> | ||
+ | The output is relatively a low distortion one due to the method of generation,<br/> | ||
+ | and a high level one with the push-pull final amplifier, two 6V6.<br/><br/> | ||
+ | In the model SG-15A for the fixed oscillator is used a xtal oscillator, instead of the LC of the SG-15<br/><br/> | ||
+ | == Images == | ||
+ | |||
+ | <gallery widths=250px heights=250px> | ||
+ | Image:SG-15_01.JPG| | ||
+ | Image:SG-15_02.JPG| | ||
+ | Image:SG-15_03.JPG| | ||
+ | Image:SG-15_04.JPG| | ||
+ | Image:SG-15_05.JPG| | ||
+ | Image:SG-15_06.JPG| | ||
+ | </gallery> | ||
==Relationship to Similar Equipment== | ==Relationship to Similar Equipment== | ||
Line 24: | Line 41: | ||
==Tubes, Crystals, Transistors== | ==Tubes, Crystals, Transistors== | ||
+ | |||
+ | <table> | ||
+ | <tr> | ||
+ | <td valign="top"> | ||
+ | SG-15/PCM | ||
*3 - 6J5 | *3 - 6J5 | ||
*1 - 6SL7GT | *1 - 6SL7GT | ||
Line 33: | Line 55: | ||
*1 - 6L6GAY | *1 - 6L6GAY | ||
*1 - 5Y3GT | *1 - 5Y3GT | ||
− | + | </td> | |
+ | <td valign="top"> | ||
+ | SG-15A/PCM | ||
+ | *1 - 6SN7 | ||
+ | *2 - 6J5 | ||
+ | *1 - 6SL7GT | ||
+ | *2 - 6V6GTY | ||
+ | *2 - 6SJ7 | ||
+ | *1 - 6SA7Y | ||
+ | *1 - 6SQ7 | ||
+ | *1 - 0C3/VR105 | ||
+ | *1 - 6L6GAY | ||
+ | *1 - 5Y3GT | ||
+ | </td> | ||
+ | </tr> | ||
+ | </table> | ||
==Reference Data and Literature== | ==Reference Data and Literature== | ||
Line 40: | Line 77: | ||
[[Category:Military/Test Equipment]] | [[Category:Military/Test Equipment]] | ||
− | {{DISPLAYTITLE: | + | {{DISPLAYTITLE:SG-15/PCM}} |
Latest revision as of 20:28, 1 April 2014
Contents
Overview
The range of frequency is generated in only one band, from 20 to 35000 Hz.
The method of generation is different from other signal generators:
the variable frequency oscillator operates from 100 to 135 Khz, its output is beated with a fixed oscillator of 100 Khz in a mixer
the output of which, filtered and amplified, is the signal at the output connector.
The output is relatively a low distortion one due to the method of generation,
and a high level one with the push-pull final amplifier, two 6V6.
In the model SG-15A for the fixed oscillator is used a xtal oscillator, instead of the LC of the SG-15
Images
Relationship to Similar Equipment
This equipment, with the signal generator ME-22/PCM, is part of Telephone Test Set TS-140/PCM.
Technical Description
- Power Requirements
- 50 w, 115 or 230 v ±10%, 50 to 70 cy, 1 phase ac
- Frequency Range
- 200 to 35,000 cy
- Frequency accuracy
- +- 10 cps from 200 to 1000 cps, +-20 cps from 1000 to 2000 cps, +-50 from 2000 to 35000 cps
- Impedance
- 600 ohms
- Power output
- -45 to +26 dbm +- 0.5 db
- Major Unit
- SG-15/PMC 19"w 13"d 8 3/4" h; 52 lbs
- Carring case
- CY-712/PCM 21 1/8"w 16 d 12 1/4 h; 30 lbs
Tubes, Crystals, Transistors
SG-15/PCM
|
SG-15A/PCM
|
Reference Data and Literature
- TM 11-2096
- MIL-T-12643