Difference between revisions of "AN~GRA-39"

From RadioNerds
Jump to navigation Jump to search
 
(23 intermediate revisions by the same user not shown)
Line 1: Line 1:
==Description==
 
 
The AN/GRA-39 is used in conjunction with a radio receiver-transmitter or a local battery switchboard to expand the interfacing capability of the radio or switchboard. When connected with a radio, the AN/GRA-39 enables the operator to transmit and receive voice frequency communications through the radio for a distance of up to two miles (3.3 kilometers) from the radio. When connected with a switchboard, the AN/GRA-39 is used 10 accomplish net radio interface (NRI), by which voice communication is established between a field telephone (switchboard subscriber) and a radio. In either application, communication can be initiated by the remote control unit operator or by the local control unit operator. Transmissions initiating at the local control unit do not involve the remote control unit. However, transmissions initiating at the remote unit require the presence of an appropriately set local unit in the system.
 
The AN/GRA-39 is used in conjunction with a radio receiver-transmitter or a local battery switchboard to expand the interfacing capability of the radio or switchboard. When connected with a radio, the AN/GRA-39 enables the operator to transmit and receive voice frequency communications through the radio for a distance of up to two miles (3.3 kilometers) from the radio. When connected with a switchboard, the AN/GRA-39 is used 10 accomplish net radio interface (NRI), by which voice communication is established between a field telephone (switchboard subscriber) and a radio. In either application, communication can be initiated by the remote control unit operator or by the local control unit operator. Transmissions initiating at the local control unit do not involve the remote control unit. However, transmissions initiating at the remote unit require the presence of an appropriately set local unit in the system.
  
Line 5: Line 4:
  
 
The local and remote control units are battery powered. The two units have identical battery requirements. Each control unit has a waterproof case, and each has two D-rings for attachment of a sling which allows the unit to be carried or hung on an appropriate object. All operating controls on each unit are located in the front panel.
 
The local and remote control units are battery powered. The two units have identical battery requirements. Each control unit has a waterproof case, and each has two D-rings for attachment of a sling which allows the unit to be carried or hung on an appropriate object. All operating controls on each unit are located in the front panel.
 +
 +
 +
[[File:C-2328_GRA-39.png|400px|Remote Control C-2328/GRA-39]]
 +
[[File:C-2329_GRA-39.png|400px|Local Control C-2329/GRA-39]]
  
  
Line 13: Line 16:
 
File:gra39r.gif
 
File:gra39r.gif
 
</gallery>
 
</gallery>
 +
  
 
==Usage==
 
==Usage==
[[File:gra-39-hookup.png | 650px | RT-524]]
+
 
 +
;Basic GRA-39 Hookup with VRC Series radios
 +
 
 +
:[[File:GRA-39_with_VRC.png]]
 +
 
  
  
[[File:gra-39-hookup-sincgars.gif | SINCGARS]]
+
;VRC / PRC Hookup with SB-22 Switchboard
  
==Additional Files==
+
:[[File:gra-39-hookup.png | 650px | RT-524]]
 +
 
 +
 
 +
 
 +
;Sincgars Hookup
 +
 
 +
:[[File:gra-39-hookup-sincgars.gif | SINCGARS]]
 +
 
 +
 
 +
 
 +
;Net Radio Interface (NRI) with GRA-39
 +
 
 +
:[[File:NRI-w_GRA-39.png|400px]]
 +
 
 +
==Reference Files==
 
;{{pdf|TM-11-5820-477-12.pdf|TM 11-5820-477-12}}
 
;{{pdf|TM-11-5820-477-12.pdf|TM 11-5820-477-12}}
 
:Operator’s and Organizational Maintenance Manual for Radio Set Control Groups  
 
:Operator’s and Organizational Maintenance Manual for Radio Set Control Groups  
Line 26: Line 48:
 
::AN/GRA-39A (NSN 5820-00-949-9909)
 
::AN/GRA-39A (NSN 5820-00-949-9909)
 
::AN/GRA-39B (NSN 5820-00-949-9909)  
 
::AN/GRA-39B (NSN 5820-00-949-9909)  
::AN/GRA-39C (NSN 5820-01-196-0204)
+
::July 1975
  
  
 
;{{pdf|GRA-39_TM-11-5820-477-23P.pdf|TM-11-5820-477-23P}}
 
;{{pdf|GRA-39_TM-11-5820-477-23P.pdf|TM-11-5820-477-23P}}
:Organizational and Direct Support Maintenance Repair Parts and Special Tools List: Radio Set Control Groups
+
:Organizational and Direct Support Maintenance Repair Parts and Special Tools List
 +
::Radio Set Control Groups
 
::AN/GRA-39 (NSN 5820-00-889-3680)
 
::AN/GRA-39 (NSN 5820-00-889-3680)
 
::AN/GRA-39A (NSN 5820-00-949-9909)
 
::AN/GRA-39A (NSN 5820-00-949-9909)
 
::AN/GRA-39B (NSN 5820-00-949-9909)
 
::AN/GRA-39B (NSN 5820-00-949-9909)
 
::AN/GRA-39C (NSN 5820-01-196-0204)
 
::AN/GRA-39C (NSN 5820-01-196-0204)
 +
::1 July 1988
  
  
Line 43: Line 67:
 
::AN/GRA-39B NSN (5820-00-949-9909)  
 
::AN/GRA-39B NSN (5820-00-949-9909)  
 
::AN/GRA-39C NSN (5820-01-196-0204)
 
::AN/GRA-39C NSN (5820-01-196-0204)
 +
::1 July 1991
 +
 +
 +
;{{pdf|TC_24-3_Radio_Wire_Integration.pdf|TC 24-3}}
 +
:Radio Wire Integration
 +
::Installation and Operation Tips
 +
::Users Guide
 +
::30 November 1976
 +
 +
 +
[[Category:Military/Radios/Accessories]]
 +
{{DISPLAYTITLE:AN/GRA-39}}

Latest revision as of 14:25, 28 April 2014

The AN/GRA-39 is used in conjunction with a radio receiver-transmitter or a local battery switchboard to expand the interfacing capability of the radio or switchboard. When connected with a radio, the AN/GRA-39 enables the operator to transmit and receive voice frequency communications through the radio for a distance of up to two miles (3.3 kilometers) from the radio. When connected with a switchboard, the AN/GRA-39 is used 10 accomplish net radio interface (NRI), by which voice communication is established between a field telephone (switchboard subscriber) and a radio. In either application, communication can be initiated by the remote control unit operator or by the local control unit operator. Transmissions initiating at the local control unit do not involve the remote control unit. However, transmissions initiating at the remote unit require the presence of an appropriately set local unit in the system.

When a handset is connected to both the local control unit and the remote control unit, two-way communication is possible between the two units independent of any radio or switchboard in the system.

The local and remote control units are battery powered. The two units have identical battery requirements. Each control unit has a waterproof case, and each has two D-rings for attachment of a sling which allows the unit to be carried or hung on an appropriate object. All operating controls on each unit are located in the front panel.


Remote Control C-2328/GRA-39 Local Control C-2329/GRA-39


Images


Usage

Basic GRA-39 Hookup with VRC Series radios
GRA-39 with VRC.png


VRC / PRC Hookup with SB-22 Switchboard
RT-524


Sincgars Hookup
SINCGARS


Net Radio Interface (NRI) with GRA-39
NRI-w GRA-39.png

Reference Files

Adobe PDF icon.png TM 11-5820-477-12

Operator’s and Organizational Maintenance Manual for Radio Set Control Groups
AN/GRA-39 (NSN 5820-00-889-3680)
AN/GRA-39A (NSN 5820-00-949-9909)
AN/GRA-39B (NSN 5820-00-949-9909)
July 1975


Adobe PDF icon.png TM-11-5820-477-23P

Organizational and Direct Support Maintenance Repair Parts and Special Tools List
Radio Set Control Groups
AN/GRA-39 (NSN 5820-00-889-3680)
AN/GRA-39A (NSN 5820-00-949-9909)
AN/GRA-39B (NSN 5820-00-949-9909)
AN/GRA-39C (NSN 5820-01-196-0204)
1 July 1988


Adobe PDF icon.png TM 11-5820-477-30

DIRECT SUPPORT MAINTENANCE MANUAL FOR CONTROL, RADIO SET GROUPS
AN/GRA-39 NSN (5820-00-889-3860)
AN/GRA-39A NSN (5820-00-082-3998)
AN/GRA-39B NSN (5820-00-949-9909)
AN/GRA-39C NSN (5820-01-196-0204)
1 July 1991


Adobe PDF icon.png TC 24-3

Radio Wire Integration
Installation and Operation Tips
Users Guide
30 November 1976