− | Test Set I-49 is a compact, sturdy, portable | + | Test Set I-49 is a compact, sturdy, portable Wheatstone bridge [https://en.wikipedia.org/wiki/Wheatstone_bridge] incorporating a number of features recommended by telephone engineers. It is rapid in operation, light in weight, and small in size. Desingned for use in the field, all contacts are inclosed, the knobs are undercut, and the dial switches have positioning stops. The switches, keys, and binding posts are placed so that an operator wearing gloves can manipulate them easily. Connections for the various loop tests and for resistance measurements are made with a singel cam type key switch. |
− | Application: a) to determine the location of a fault on a circuit | + | *'''Application''': |
− | + | * a) to determine the location of a fault on a circuit, | |
− | + | *b) to determine whether or not a circuit is in normal condition, | |
− | + | *c) to measure unknown resistance, | |
− | Dimensions: 8,7/8 by 7,3/8 by 5,3/4 inches | + | *d) as an auxiliary resistance box |
− | Weight : approximately 8 pounds | + | |
+ | *'''Dimensions''': 8,7/8 by 7,3/8 by 5,3/4 inches | ||
+ | *'''Weight''' : approximately 8 pounds | ||
[[File:I-49.jpg|400px]] | [[File:I-49.jpg|400px]] | ||
− | [[File:I-49.2.jpg]] | + | [[File:I-49.2.jpg|300px]] |
==References== | ==References== | ||
* {{pdf|TM 11-2019 1944.pdf|TM 11-2019 Aug. 1944}} TEST SETS, I-49, I-49-A AND I-49-B AND RESISTANCE BRIDGES, ZM-4 AND ZM-4B/U TO 33A1-12-15-1 | * {{pdf|TM 11-2019 1944.pdf|TM 11-2019 Aug. 1944}} TEST SETS, I-49, I-49-A AND I-49-B AND RESISTANCE BRIDGES, ZM-4 AND ZM-4B/U TO 33A1-12-15-1 |
Latest revision as of 05:38, 5 December 2015
Test Set I-49 is a compact, sturdy, portable Wheatstone bridge [1] incorporating a number of features recommended by telephone engineers. It is rapid in operation, light in weight, and small in size. Desingned for use in the field, all contacts are inclosed, the knobs are undercut, and the dial switches have positioning stops. The switches, keys, and binding posts are placed so that an operator wearing gloves can manipulate them easily. Connections for the various loop tests and for resistance measurements are made with a singel cam type key switch.
- Application:
- a) to determine the location of a fault on a circuit,
- b) to determine whether or not a circuit is in normal condition,
- c) to measure unknown resistance,
- d) as an auxiliary resistance box
- Dimensions: 8,7/8 by 7,3/8 by 5,3/4 inches
- Weight : approximately 8 pounds
References