Difference between revisions of "TA-1035~U"
Jump to navigation
Jump to search
RadioNerds (talk | contribs) |
RadioNerds (talk | contribs) |
||
Line 1: | Line 1: | ||
− | + | [[File:TA-1035-U.png]] | |
− | |||
==Description== | ==Description== | ||
As a prime subscriber terminal, the TA-1035/U provides full-duplex, conditioned, diphase digital voice and loop signaling information with wire and mobile access equipment. It also provides supervisory, clock, plain text, and voltage reference signals with data devices. The TA-1035/U provides a data port for interfacing the communications terminal (CT) and AN/UXC-7 data devices to the echelons corps and below (ECB) network. The TA-1035/U operates in a common-battery power mode, deriving its power from the switch line termination circuit. | As a prime subscriber terminal, the TA-1035/U provides full-duplex, conditioned, diphase digital voice and loop signaling information with wire and mobile access equipment. It also provides supervisory, clock, plain text, and voltage reference signals with data devices. The TA-1035/U provides a data port for interfacing the communications terminal (CT) and AN/UXC-7 data devices to the echelons corps and below (ECB) network. The TA-1035/U operates in a common-battery power mode, deriving its power from the switch line termination circuit. |
Revision as of 22:17, 31 May 2013
Contents
Description
As a prime subscriber terminal, the TA-1035/U provides full-duplex, conditioned, diphase digital voice and loop signaling information with wire and mobile access equipment. It also provides supervisory, clock, plain text, and voltage reference signals with data devices. The TA-1035/U provides a data port for interfacing the communications terminal (CT) and AN/UXC-7 data devices to the echelons corps and below (ECB) network. The TA-1035/U operates in a common-battery power mode, deriving its power from the switch line termination circuit.
Technical Characteristics
Cables
- Channel interface
-
- 4 conductor field wire, 1,000 ft max (305)
- Data device interface
- Signal cable
Power Requirements
- Input power (power drain)
- On-hook
- 300 mW, max
- Off-hook
- 1.5W, max
- Input power (voltage)
- +24to+56VDC
- Input power (current drain)
- On-hook
- 12.5mA@+24VDC / 5.0 mA @ +56 V DC
- Off-hook
- 62mA@+24VDC 25 mA @ +56 V DC
Weights and Dimensions
- Length
- 10 in (257.0mm)
- Width
- 7-3/8 in (185.9mm)
- Height
- 4-5/8 in (118.9mm)
- Weight
- 5-3/4 lb (2.6kg)
Related Files
- TM 11-5805-761-13&P
- TELEPHONE, DIGITAL, NON-SECURE
- TA-1035/U (NSN 5805-01-246-6826)
- 9 January 1995
- (presently under restricted distribution)