(Created page with "==References== * TM 11-5500 Multimeter TS-297/U. Dept. of the Army and the Air Force. Aug. 1948. 37 p. U408.3.A13 TM 11-5500 Aug. 1948")
 
 
Line 1: Line 1:
 +
Multimeter TS-297/U is a portable test instrument used in the maintenance and repair of electronicequipment. It checks voltage, current or resistance.
 +
It replaced Test Set [[I-77]], Test Unit [[I-236]] and Multimeters [[I-239]] and [[TS-380]]/U. 
 +
Required Battery [[BA-42]]
 +
 +
[[File:TS-297.U Multimeter.jpg]]
 +
 +
TECHNICAL DESCRIPTION:
 +
;Pwr Requirements: 1.5 v dc Voltage Range: 0 to 4, 10, 40, 100, 400, 1,000 v ac, dc
 +
;Current Range: 0 to 4, 40, 100, 400 ma dc
 +
;Resistance Range: 0 to 1,000; 10,000; 100,000 ohms
 +
;Sensitivity: 1,000 ohms/v Major Units: 1 TS-297/U 6 1/8" x 3 1/4" x 3 1/4"; 3.3 lbs
 +
 +
 
==References==
 
==References==
 
* TM 11-5500 Multimeter TS-297/U. Dept. of the Army and the Air Force. Aug. 1948. 37 p. U408.3.A13 TM 11-5500 Aug. 1948
 
* TM 11-5500 Multimeter TS-297/U. Dept. of the Army and the Air Force. Aug. 1948. 37 p. U408.3.A13 TM 11-5500 Aug. 1948
 +
 +
* TO 16-2CCB-1,
 +
 +
* TO 16-35TS297-5
 +
 +
* MIL-M-10263

Latest revision as of 17:18, 14 June 2018

Multimeter TS-297/U is a portable test instrument used in the maintenance and repair of electronicequipment. It checks voltage, current or resistance. It replaced Test Set I-77, Test Unit I-236 and Multimeters I-239 and TS-380/U. Required Battery BA-42

TS-297.U Multimeter.jpg

TECHNICAL DESCRIPTION:

Pwr Requirements
1.5 v dc Voltage Range: 0 to 4, 10, 40, 100, 400, 1,000 v ac, dc
Current Range
0 to 4, 40, 100, 400 ma dc
Resistance Range
0 to 1,000; 10,000; 100,000 ohms
Sensitivity
1,000 ohms/v Major Units: 1 TS-297/U 6 1/8" x 3 1/4" x 3 1/4"; 3.3 lbs


References

  • TM 11-5500 Multimeter TS-297/U. Dept. of the Army and the Air Force. Aug. 1948. 37 p. U408.3.A13 TM 11-5500 Aug. 1948
  • TO 16-2CCB-1,
  • TO 16-35TS297-5
  • MIL-M-10263