Difference between revisions of "AN~MTC-1"
(21 intermediate revisions by the same user not shown) | |||
Line 1: | Line 1: | ||
− | The AN/MTC-1 and -1A were air- or vehicular-transportable manual central offices which provided switching for 196 local battery or common battery subscriber lines and 20 manual or dial trunk circuits. The AN/MTC-1 | + | The AN/MTC-1 and -1A were air- or vehicular-transportable manual central offices which provided switching for 196 local battery or common battery subscriber lines and 20 manual or dial trunk circuits. The AN/MTC-1 and the -1A were each housed in two shelters, the AN/MTA-3 and AN/MTA-4. The |
MTA-3 contained three parallel switchboard positions. The AN/MTA-4 housed the relays, frames, storage batteries, and power panel. The AN/MTC-1 or the -1A was used at signal centers in the corps area communication systems. | MTA-3 contained three parallel switchboard positions. The AN/MTA-4 housed the relays, frames, storage batteries, and power panel. The AN/MTC-1 or the -1A was used at signal centers in the corps area communication systems. | ||
Line 6: | Line 6: | ||
'''AN/MTC-1''' : | '''AN/MTC-1''' : | ||
− | 1 Shelter [[S-179]]/MTA-3 (modified [[S-141]]/G) | + | 1 Shelter [[S-179]]/MTA-3 (modified [[S-141]]/G), later [[S-179]]/MTA-3A (modified [[S-141]]B/G) |
− | 3 | + | 3 Switchboards [[SB-249]]A/TTC |
− | 3 Telephone | + | 3 Telephone Sets [[TA-312]]/PT |
− | 1 Shelter [[S-180]]/MTA-4 (modified [[S-141]]/G) | + | 1 Shelter [[S-180]]/MTA-4 (modified [[S-141]]/G), later [[S-180]]/MTA-4A (modified [[S-141]]B/G) |
− | Main Distribution | + | 3 Main Distribution Frames [[TA-257]]/TTC |
− | Line | + | 2 Line Relays [[TA-223]]A/TTC |
− | Line Relay [[TA-226]]A/TTC | + | 1 Line Relay [[TA-226]]A/TTC |
− | Power Distribution Panel [[SB-1032]]/TTC | + | 1 Power Distribution Panel [[SB-1032]]/TTC |
− | + | 4 Batteries [[BB-46]] | |
− | Telephone | + | 3 Telephone Sets [[TA-312]]/PT |
'''AN/MTC-1A''': | '''AN/MTC-1A''': | ||
− | 1 Shelter [[S-280]]B/G | + | 1 Shelter [[S-365]]/MTA-3B (modified [[S-280]]B/G) |
− | 3 | + | 3 Switchboards [[SB-1398]]/GTA |
− | 2 Telephone | + | 2 Telephone Sets [[TA-312]]/PT |
− | 1 Shelter [[S-280]]B/G | + | 1 Shelter [[S-366]]/MTA-4B (modified [[S-280]]B/G) |
− | Main Distribution | + | 3 Main Distribution Frames [[TA-454]]/GTA-14 |
− | Line | + | 2 Line Relays [[TA-452]]/GTA-14 |
− | Line Relay [[TA-226]]/TTC | + | 1 Line Relay [[TA-226]]/TTC |
− | Power Distribution Panel [[SB-1399]]/GTA | + | 1 Power Distribution Panel [[SB-1399]]/GTA |
− | + | 4 Batteries [[BB-46]] | |
+ | |||
+ | 3 Telephone Sets [[TA-312]]/PT | ||
+ | |||
+ | 2 Intercommunication Stations [[LS-147]]F/FI | ||
− | |||
− | |||
[[File:AN.MTC-1 AND 1A.2.jpg]] | [[File:AN.MTC-1 AND 1A.2.jpg]] | ||
− | Early MTC-1 configuration: | + | Early MTC-1 configuration (The shelters are the early version [[S-141]]/G, before the [[S-141]]B/G appeared): |
[[File:AN.MTC-1 AND 1A.3.jpg]] | [[File:AN.MTC-1 AND 1A.3.jpg]] | ||
Line 62: | Line 64: | ||
[[S-180]] | [[S-180]] | ||
+ | |||
+ | [[AN~MTA-3A]] | ||
+ | |||
+ | [[AN~MTA-4A]] | ||
+ | |||
+ | [[AN~MTA-3B]] | ||
+ | |||
+ | [[AN~MTA-4B]] | ||
==Reference Files== | ==Reference Files== | ||
− | * TM 11-5805-284 | + | * TM 11-5805-284-14 |
+ | |||
+ | * TM 11-5805-284-15 | ||
+ | |||
+ | {{DISPLAYTITLE: AN/MTC-1}} |
Latest revision as of 19:15, 14 July 2019
The AN/MTC-1 and -1A were air- or vehicular-transportable manual central offices which provided switching for 196 local battery or common battery subscriber lines and 20 manual or dial trunk circuits. The AN/MTC-1 and the -1A were each housed in two shelters, the AN/MTA-3 and AN/MTA-4. The MTA-3 contained three parallel switchboard positions. The AN/MTA-4 housed the relays, frames, storage batteries, and power panel. The AN/MTC-1 or the -1A was used at signal centers in the corps area communication systems.
Major Components
AN/MTC-1 :
1 Shelter S-179/MTA-3 (modified S-141/G), later S-179/MTA-3A (modified S-141B/G)
3 Switchboards SB-249A/TTC
3 Telephone Sets TA-312/PT
1 Shelter S-180/MTA-4 (modified S-141/G), later S-180/MTA-4A (modified S-141B/G)
3 Main Distribution Frames TA-257/TTC
2 Line Relays TA-223A/TTC
1 Line Relay TA-226A/TTC
1 Power Distribution Panel SB-1032/TTC
4 Batteries BB-46
3 Telephone Sets TA-312/PT
AN/MTC-1A:
1 Shelter S-365/MTA-3B (modified S-280B/G)
3 Switchboards SB-1398/GTA
2 Telephone Sets TA-312/PT
1 Shelter S-366/MTA-4B (modified S-280B/G)
3 Main Distribution Frames TA-454/GTA-14
2 Line Relays TA-452/GTA-14
1 Line Relay TA-226/TTC
1 Power Distribution Panel SB-1399/GTA
4 Batteries BB-46
3 Telephone Sets TA-312/PT
2 Intercommunication Stations LS-147F/FI
Early MTC-1 configuration (The shelters are the early version S-141/G, before the S-141B/G appeared):
See Also
Reference Files
- TM 11-5805-284-14
- TM 11-5805-284-15