Difference between revisions of "M-222"
RadioNerds (talk | contribs) |
RadioNerds (talk | contribs) |
||
(4 intermediate revisions by the same user not shown) | |||
Line 3: | Line 3: | ||
Converter M- 222 is designed to supply emergency power ringing current for telephone switchboards such as Switchboards BD-91-( ) and BD-96, when power from a 110-volt, 60 cycle source is not available or when the standard 110-volt power ringing equipment fails in service. Converter M- 222 is a component of Telephone Central Office Sets TC- 4 and TC-12. | Converter M- 222 is designed to supply emergency power ringing current for telephone switchboards such as Switchboards BD-91-( ) and BD-96, when power from a 110-volt, 60 cycle source is not available or when the standard 110-volt power ringing equipment fails in service. Converter M- 222 is a component of Telephone Central Office Sets TC- 4 and TC-12. | ||
− | + | ==Technical Characteristics== | |
− | + | ===Power Source=== | |
− | + | Converter M-222 uses two 1 1/2-volt Batteries BA-23, connected in series, as a source of power. Battery life is approximately 8 to 10 hours under continuous operation. | |
− | |||
+ | ===Output Voltage and Frequency=== | ||
+ | The output of Converter M-222 is 100 volts alternating current open circuit, or 50 volts with a 5-watt load. The peak voltage will not exceed 250 volts. The frequency of the output voltage is 24 cycles ± 4 cycles. | ||
===Description=== | ===Description=== | ||
− | Converter M-222 consists essentially of the following assemblies: | + | Converter M-222 consists essentially of the following assemblies: Box. Converter M-222 is housed in a rectangular steel box with two removable sides. On the front panel are mounted an output receptacle, a nameplate, the lower section of one catch fastener, and Switch SW- 105. The switch is mounted in a recess in the panel. The ON and OFF positions of the switch are marked on the panel. |
− | |||
[[File:M-222_7.png|400px|center]] | [[File:M-222_7.png|400px|center]] |
Latest revision as of 12:50, 20 September 2013
Contents
Overview
Application Converter M- 222 is designed to supply emergency power ringing current for telephone switchboards such as Switchboards BD-91-( ) and BD-96, when power from a 110-volt, 60 cycle source is not available or when the standard 110-volt power ringing equipment fails in service. Converter M- 222 is a component of Telephone Central Office Sets TC- 4 and TC-12.
Technical Characteristics
Power Source
Converter M-222 uses two 1 1/2-volt Batteries BA-23, connected in series, as a source of power. Battery life is approximately 8 to 10 hours under continuous operation.
Output Voltage and Frequency
The output of Converter M-222 is 100 volts alternating current open circuit, or 50 volts with a 5-watt load. The peak voltage will not exceed 250 volts. The frequency of the output voltage is 24 cycles ± 4 cycles.
Description
Converter M-222 consists essentially of the following assemblies: Box. Converter M-222 is housed in a rectangular steel box with two removable sides. On the front panel are mounted an output receptacle, a nameplate, the lower section of one catch fastener, and Switch SW- 105. The switch is mounted in a recess in the panel. The ON and OFF positions of the switch are marked on the panel.
Images
Related Files
- Technical Manual
- Converter
- M-222
- March 16, 1943
- Technical Manual
- Converter
- M-222
- April 1946