RadioNerds (talk | contribs) (Created page with " File:an~pps-6.png ==Operating Instructions== These operating instructions are found printed on the data plate attached to the unit. OPERATING INSTRUCTIONS RADAR SET A...") |
RadioNerds (talk | contribs) |
||
(14 intermediate revisions by the same user not shown) | |||
Line 1: | Line 1: | ||
− | [[File:an~pps-6.png]] | + | [[File:an~pps-6.png|400px]] |
==Operating Instructions== | ==Operating Instructions== | ||
These operating instructions are found printed on the data plate attached to the unit. | These operating instructions are found printed on the data plate attached to the unit. | ||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
===Starting the Equipment=== | ===Starting the Equipment=== | ||
Line 21: | Line 15: | ||
#Adjust <u>Sensitivity</u> control so that <u>Test Meter</u> points to <u>AGC</u> line. | #Adjust <u>Sensitivity</u> control so that <u>Test Meter</u> points to <u>AGC</u> line. | ||
#Loosen <u>Elevation</u> knob and adjust radar for maximum <u>AGC</u> deflection on <u>Test Meter</u> while adjusting <u>Sensitivity</u> control to maintain meter pointer near <u>AGC</u> line. | #Loosen <u>Elevation</u> knob and adjust radar for maximum <u>AGC</u> deflection on <u>Test Meter</u> while adjusting <u>Sensitivity</u> control to maintain meter pointer near <u>AGC</u> line. | ||
− | #Set <u>Area Search</u> switch <u>(Mode 1-2-3)</u> to <u>Mode 1</u> or <u>2</u> as desired, and <u>Auto-Man</u> clutch to | + | #Set <u>Area Search</u> switch <u>(Mode 1-2-3)</u> to <u>Mode 1</u> or <u>2</u> as desired, and <u>Auto-Man</u> clutch to <u>Man</u> position. |
− | <u>Man</u> position. | ||
#On Angular control, adjust sector scan ring to center of desired scanning sector. | #On Angular control, adjust sector scan ring to center of desired scanning sector. | ||
#Manually scan desired sector by moving receiver transmitter unit to azimuth. With radar trained on spot giving lowest reading, adjust <u>Sensitivity</u> control so that <u>Test Meter</u> pointer is on <u>AGC</u> line. Lock <u>Sensitivity</u> control. | #Manually scan desired sector by moving receiver transmitter unit to azimuth. With radar trained on spot giving lowest reading, adjust <u>Sensitivity</u> control so that <u>Test Meter</u> pointer is on <u>AGC</u> line. Lock <u>Sensitivity</u> control. | ||
#Again, Manually scan desired sector and set <u>Volume</u> control for satisfactory max noise level in headset. | #Again, Manually scan desired sector and set <u>Volume</u> control for satisfactory max noise level in headset. | ||
#Set <u>Auto-Man</u> clutch to <u>Auto</u> position and monitor headset for moving target in area under surveillance. | #Set <u>Auto-Man</u> clutch to <u>Auto</u> position and monitor headset for moving target in area under surveillance. | ||
+ | |||
+ | {{message|NOTE|Make sure that low meter reading is not caused by blocking of radar beam by large fixed targets in front of desired target area}} | ||
===Stopping the Equipment=== | ===Stopping the Equipment=== | ||
# Place <u>Power</u> switch <u>(OFF-STBY-XMIT)</u> at <u>OFF</u> position. | # Place <u>Power</u> switch <u>(OFF-STBY-XMIT)</u> at <u>OFF</u> position. | ||
+ | |||
+ | ==Reference Files== | ||
+ | ;{{cecom_pdf|USAELRDL Technical Report 2421.pdf|USAELRDL Technical Report 2421}} | ||
+ | :Assembly Design of Miniature Lightweight Handheld Radar Set AN/PPS-6 | ||
+ | ::HARRY H. FRENCH | ||
+ | ::UNITED STATES ARMY | ||
+ | ::ELECTRONICS RESEARCH AND DEVELOPMENT LABORATORIES FORT MONMOUTH, N.J. | ||
+ | ::SEPTEMBER 1963 | ||
+ | |||
+ | |||
+ | ;{{cecom_pdf|DESIGN PARAMETERS FOR A LIGHTWEIGHT HANDHELD RADAR SYSTEM AN-PPS-6.pdf|DESIGN PARAMETERS FOR A LIGHTWEIGHT HANDHELD RADAR SYSTEM AN/PPS-6( )}} | ||
+ | :Army Signal Research and Development Laboratory Fort Monmouth, New Jersey | ||
+ | ::Dunlap and Associates, Inc. 429 Atlantic Street Stamford, Connecticut | ||
+ | ::Leroy L. Vallerie | ||
+ | ::Robert T. McCay | ||
+ | ::Jack Wm. Dunlap, Program Director | ||
+ | ::January 1962 | ||
+ | |||
+ | |||
+ | ;{{cecom_pdf|Research and Development Technical Report ECOM - 00390.pdf|Research and Development Technical Report ECOM - 00390}} | ||
+ | :FINAL REPORT | ||
+ | ::RADAR SET | ||
+ | ::AN/PPS-6(XE-6) | ||
+ | ::11 OCTOBER 1964 to 24 JUNE 1966 | ||
+ | ::June 1967 | ||
+ | |||
+ | |||
+ | ;{{pdf|Interim_development_Report-3-3-70_RCA-AN-PPS-6 Radar.pdf|Interim Development Report for AN/PPS-( ) Ultra Reliable Radar}} | ||
+ | :Prepared by | ||
+ | :RCA Corporation | ||
+ | ::Defense Electronic Products | ||
+ | ::Missile and Surface Radar Division | ||
+ | ::6 April 1970 | ||
+ | |||
+ | |||
+ | ;{{cecom_pdf|an-pps-6_misc_articles.pdf|Misc Articles and Documents AN/PPS-6}} | ||
+ | |||
+ | ==References== | ||
+ | <references /> | ||
[[Category:Military/Radars]] | [[Category:Military/Radars]] | ||
{{DISPLAYTITLE: AN/PPS-6}} | {{DISPLAYTITLE: AN/PPS-6}} |
Latest revision as of 01:41, 7 May 2014
Contents
Operating Instructions
These operating instructions are found printed on the data plate attached to the unit.
Starting the Equipment
- Set meter switch to BAT position and check battery condition on Test Meter
- Set Power switch (OFF-STBY-XMIT) at XMT position.
- Set Area Search switch (MODE 1-2-3) at MODE 3
- Set Adjust Range Control knob to estimated center (in meters) of desired target area
- Set Meter switch to AGC/EL position
- Sight on desired sector, using front and rear sights
- Adjust Sensitivity control so that Test Meter points to AGC line.
- Loosen Elevation knob and adjust radar for maximum AGC deflection on Test Meter while adjusting Sensitivity control to maintain meter pointer near AGC line.
- Set Area Search switch (Mode 1-2-3) to Mode 1 or 2 as desired, and Auto-Man clutch to Man position.
- On Angular control, adjust sector scan ring to center of desired scanning sector.
- Manually scan desired sector by moving receiver transmitter unit to azimuth. With radar trained on spot giving lowest reading, adjust Sensitivity control so that Test Meter pointer is on AGC line. Lock Sensitivity control.
- Again, Manually scan desired sector and set Volume control for satisfactory max noise level in headset.
- Set Auto-Man clutch to Auto position and monitor headset for moving target in area under surveillance.
Stopping the Equipment
- Place Power switch (OFF-STBY-XMIT) at OFF position.
Reference Files
- USAELRDL Technical Report 2421[1]
- Assembly Design of Miniature Lightweight Handheld Radar Set AN/PPS-6
- HARRY H. FRENCH
- UNITED STATES ARMY
- ELECTRONICS RESEARCH AND DEVELOPMENT LABORATORIES FORT MONMOUTH, N.J.
- SEPTEMBER 1963
- DESIGN PARAMETERS FOR A LIGHTWEIGHT HANDHELD RADAR SYSTEM AN/PPS-6( )[2]
- Army Signal Research and Development Laboratory Fort Monmouth, New Jersey
- Dunlap and Associates, Inc. 429 Atlantic Street Stamford, Connecticut
- Leroy L. Vallerie
- Robert T. McCay
- Jack Wm. Dunlap, Program Director
- January 1962
- Research and Development Technical Report ECOM - 00390[3]
- FINAL REPORT
- RADAR SET
- AN/PPS-6(XE-6)
- 11 OCTOBER 1964 to 24 JUNE 1966
- June 1967
Interim Development Report for AN/PPS-( ) Ultra Reliable Radar
- Prepared by
- RCA Corporation
- Defense Electronic Products
- Missile and Surface Radar Division
- 6 April 1970
References
- ↑ USAELRDL Technical Report 2421,
- "US Army Technical Manual Collection,"
- from the CECOM Historical Office archive, Aberdeen Proving Ground, MD.
- CECOM Historical Office
- "US Army Technical Manual Collection,"
- ↑ DESIGN PARAMETERS FOR A LIGHTWEIGHT HANDHELD RADAR SYSTEM AN/PPS-6( ),
- "US Army Technical Manual Collection,"
- from the CECOM Historical Office archive, Aberdeen Proving Ground, MD.
- CECOM Historical Office
- "US Army Technical Manual Collection,"
- ↑ Research and Development Technical Report ECOM - 00390,
- "US Army Technical Manual Collection,"
- from the CECOM Historical Office archive, Aberdeen Proving Ground, MD.
- CECOM Historical Office
- "US Army Technical Manual Collection,"
- ↑ Misc Articles and Documents AN/PPS-6,
- "US Army Technical Manual Collection,"
- from the CECOM Historical Office archive, Aberdeen Proving Ground, MD.
- CECOM Historical Office
- "US Army Technical Manual Collection,"