Difference between revisions of "DM - Dynamotor"
Jump to navigation
Jump to search
(28 intermediate revisions by the same user not shown) | |||
Line 1: | Line 1: | ||
DM - Dynamotor | DM - Dynamotor | ||
− | * [[DM-1]] 10 to 300 Volts | + | * [[DM-1]] 10 to 300 Volts [[SCR-79]], [[SCR-99]] |
− | * [[DM-2]] same as 1 | + | * [[DM-2]] same as DM-1 |
− | * [[DM-3]] 10 to 300 Volts | + | * [[DM-3]] 10 to 300 Volts, same as DM-1 |
− | * [[DM-4]] [[BC-25]] | + | * [[DM-4]] [[BC-25]] case, and DM-1. |
* [[DM-5]] ? | * [[DM-5]] ? | ||
* [[DM-6]] 12 to 350 Volts [[SCR-68]] | * [[DM-6]] 12 to 350 Volts [[SCR-68]] | ||
* [[DM-7]] 21.5 to 465 Volts | * [[DM-7]] 21.5 to 465 Volts | ||
* [[DM-8]] DC. to AC. 12 to 120 Volts [[SCR-62]] | * [[DM-8]] DC. to AC. 12 to 120 Volts [[SCR-62]] | ||
− | * [[DM-9]] 10 to 300 Volts | + | * [[DM-9]] 10 to 300 Volts, same as DM-1. |
* [[DM-10]] ? | * [[DM-10]] ? | ||
* [[DM-11]] Booster type motor generator [[Telautograph]] | * [[DM-11]] Booster type motor generator [[Telautograph]] | ||
Line 15: | Line 15: | ||
(NOTE- 1920 storage cataloge ends here) | (NOTE- 1920 storage cataloge ends here) | ||
* [[DM-13]], [[SCR-109]], [[SCR-159]] | * [[DM-13]], [[SCR-109]], [[SCR-159]] | ||
− | * [[DM-14]] | + | * [[DM-14]], 12 Volt (only reference is in 1925 National commodities catalog) [[BD-43]] ? |
− | * [[DM-15]] | + | * [[DM-15]] DM()15, 1931 ? |
* [[DM-16]] | * [[DM-16]] | ||
* [[DM-17]], [[BC-312]], [[BC-314]], [[SCR-177]] | * [[DM-17]], [[BC-312]], [[BC-314]], [[SCR-177]] | ||
− | * [[DM-18]], [[BC-310]], [[SCR-242]] | + | * [[DM-18]], 14 Volt, [[BC-310]], [[SCR-242]] |
* [[DM-19]], [[BC-223]], [[SCR-245]] | * [[DM-19]], [[BC-223]], [[SCR-245]] | ||
− | * [[DM-20]], | + | * [[DM-20]], 14vdc [[SCR-280]], [[BC-431]] radio compass |
* [[DM-21]], [[BC-312]], [[BC-314]], [[SCR-177]] | * [[DM-21]], [[BC-312]], [[BC-314]], [[SCR-177]] | ||
* [[DM-22]], [[SCR-240]], [[BC-225]] | * [[DM-22]], [[SCR-240]], [[BC-225]] | ||
* [[DM-23]], [[SCR-261]], [[BC-352]] | * [[DM-23]], [[SCR-261]], [[BC-352]] | ||
− | * [[DM-24]], [[BC- | + | * [[DM-24]], 14 Volt, [[BC-224]] |
* [[DM-25]], [[BC-267]] or [[BC-367]] interphone amplifiers, | * [[DM-25]], [[BC-267]] or [[BC-367]] interphone amplifiers, | ||
− | * [[DM-26]] | + | * [[DM-26]], [[BC-394]], [[SCR-274]] |
− | * [[DM-27]] | + | * [[DM-27]], [[BC-396]], [[SCR-274]] |
− | * [[DM-28]], [[BC-348]] | + | * [[DM-28]], 24 volt, [[BC-348]] |
− | * [[DM-29]] | + | * [[DM-29]], 12 volt, [[BC-373]], [[SCR-246]] |
− | * [[DM-30]] | + | * [[DM-30]], 24 Volt, [[BC-443]], [[SCR-263]] |
− | * [[DM-31]] | + | * [[DM-31]], [[BC-420]] [[RC-48]] |
− | * [[DM-32]], | + | * [[DM-32]], 28vdc [[SCR-274]]N receiver |
* [[DM-33]], [[BC-456]], [[SCR-274]] | * [[DM-33]], [[BC-456]], [[SCR-274]] | ||
− | * [[DM-34]], 12 Volt [[SCR-508]] | + | * [[DM-34]], 12 Volt [[BC-604]], [[SCR-508]] |
− | * [[DM-35]], 12 Volt [[SCR-508]] | + | * [[DM-35]], 12 Volt [[BC-603]], [[SCR-508]] |
− | * [[DM-36]], 24 Volt [[SCR-508]] | + | * [[DM-36]], 24 Volt [[BC-604]], [[SCR-508]] |
− | * [[DM-37]], 24 Volt [[SCR-508]] | + | * [[DM-37]], 24 Volt [[BC-603]], [[SCR-508]] |
* [[DM-38]] | * [[DM-38]] | ||
− | * [[DM-39]] | + | * [[DM-39]], 24 Volt, [[BC-383]], [[SCR-276]] |
* [[DM-40]], 12 Volt, [[BC-652]], [[SCR-506]] | * [[DM-40]], 12 Volt, [[BC-652]], [[SCR-506]] | ||
* [[DM-41]], 24 volt, [[BC-652]], [[SCR-506]] | * [[DM-41]], 24 volt, [[BC-652]], [[SCR-506]] | ||
Line 54: | Line 54: | ||
* [[DM-51]] | * [[DM-51]] | ||
* [[DM-52]] | * [[DM-52]] | ||
− | * [[DM-53]],12 or 24 | + | * [[DM-53]],12 or 24 Volt, [[BC-733]], [[RC-103]] |
− | * [[DM-54]] | + | * [[DM-54]], 6 Volt, [[BC-683]], [[SCR-608]] |
− | * [[DM-55]] | + | * [[DM-55]], 6 Volt, [[BC-684]], [[SCR-608]] |
* [[DM-56]], [[SCR-549]], [[SCR-550]] | * [[DM-56]], [[SCR-549]], [[SCR-550]] | ||
* [[DM-57]] | * [[DM-57]] | ||
Line 65: | Line 65: | ||
* [[DM-62]] | * [[DM-62]] | ||
* [[DM-63]] | * [[DM-63]] | ||
− | * [[DM-64]] 12 Volt [[BC-923]] | + | * [[DM-64]] 12 Volt [[BC-923]], [[SCR-828]] |
− | * [[DM-65]] | + | * [[DM-65]] 12 Volt [[BC-924]], [[SCR-828]] |
* [[DM-66]] 24 Volt [[BC-923]] | * [[DM-66]] 24 Volt [[BC-923]] | ||
* [[DM-67]] | * [[DM-67]] | ||
Line 72: | Line 72: | ||
* [[DM-69]] | * [[DM-69]] | ||
* [[DM-70]] | * [[DM-70]] | ||
− | + | * [[DM-77]], [[AN~AIC-10]] ? | |
[[Category:Equipment Group]] | [[Category:Equipment Group]] |
Latest revision as of 14:36, 4 September 2019
DM - Dynamotor
- DM-1 10 to 300 Volts SCR-79, SCR-99
- DM-2 same as DM-1
- DM-3 10 to 300 Volts, same as DM-1
- DM-4 BC-25 case, and DM-1.
- DM-5 ?
- DM-6 12 to 350 Volts SCR-68
- DM-7 21.5 to 465 Volts
- DM-8 DC. to AC. 12 to 120 Volts SCR-62
- DM-9 10 to 300 Volts, same as DM-1.
- DM-10 ?
- DM-11 Booster type motor generator Telautograph
- DM-12 Booster type motor generator Telautograph
(NOTE- 1920 storage cataloge ends here)
- DM-13, SCR-109, SCR-159
- DM-14, 12 Volt (only reference is in 1925 National commodities catalog) BD-43 ?
- DM-15 DM()15, 1931 ?
- DM-16
- DM-17, BC-312, BC-314, SCR-177
- DM-18, 14 Volt, BC-310, SCR-242
- DM-19, BC-223, SCR-245
- DM-20, 14vdc SCR-280, BC-431 radio compass
- DM-21, BC-312, BC-314, SCR-177
- DM-22, SCR-240, BC-225
- DM-23, SCR-261, BC-352
- DM-24, 14 Volt, BC-224
- DM-25, BC-267 or BC-367 interphone amplifiers,
- DM-26, BC-394, SCR-274
- DM-27, BC-396, SCR-274
- DM-28, 24 volt, BC-348
- DM-29, 12 volt, BC-373, SCR-246
- DM-30, 24 Volt, BC-443, SCR-263
- DM-31, BC-420 RC-48
- DM-32, 28vdc SCR-274N receiver
- DM-33, BC-456, SCR-274
- DM-34, 12 Volt BC-604, SCR-508
- DM-35, 12 Volt BC-603, SCR-508
- DM-36, 24 Volt BC-604, SCR-508
- DM-37, 24 Volt BC-603, SCR-508
- DM-38
- DM-39, 24 Volt, BC-383, SCR-276
- DM-40, 12 Volt, BC-652, SCR-506
- DM-41, 24 volt, BC-652, SCR-506
- DM-42, 12 Volt, BC-653, SCR-506
- DM-43, 24 Volt, BC-653, SCR-506
- DM-44
- DM-45, 24 Volt, BC-367, BC-667 p/o RC-99
- DM-46
- DM-47, 24 Volt, BC-924, SCR-808
- DM-48
- DM-49, upgrade for BC-223
- DM-50
- DM-51
- DM-52
- DM-53,12 or 24 Volt, BC-733, RC-103
- DM-54, 6 Volt, BC-683, SCR-608
- DM-55, 6 Volt, BC-684, SCR-608
- DM-56, SCR-549, SCR-550
- DM-57
- DM-58
- DM-59
- DM-60
- DM-61
- DM-62
- DM-63
- DM-64 12 Volt BC-923, SCR-828
- DM-65 12 Volt BC-924, SCR-828
- DM-66 24 Volt BC-923
- DM-67
- DM-68
- DM-69
- DM-70
- DM-77, AN~AIC-10 ?