Difference between revisions of "TS-125~AP"
Jump to navigation
Jump to search
(3 intermediate revisions by the same user not shown) | |||
Line 1: | Line 1: | ||
[[File:TS125_AP.png|400px|right]] | [[File:TS125_AP.png|400px|right]] | ||
==Overview== | ==Overview== | ||
− | Power Meter | + | Power Meter TS-125/AP is a compact, lightweight, battery-operated, UHF wattmeter used in checking the relative power output or radar transmitters. It may also be employed in measuring antenna radiation patterns and standing wave ratios. |
This equipment consists of a temperature-compensated thermistor bridge, a milliwattmeter, and a horn-type pickup antenna. | This equipment consists of a temperature-compensated thermistor bridge, a milliwattmeter, and a horn-type pickup antenna. | ||
==Relationship to Similar Equipment== | ==Relationship to Similar Equipment== | ||
− | This equipment is part of Test Set AN | + | This equipment is part of Test Set [[AN~APM-33]], Test Set [[AN~MPM-2]], and Test Kit AN/UPM1-7. |
Equipment Required But -Not Supplied: Battery: (3) BA-30. | Equipment Required But -Not Supplied: Battery: (3) BA-30. | ||
Line 32: | Line 32: | ||
[[Category:Military/Test Equipment]] | [[Category:Military/Test Equipment]] | ||
− | {{DISPLAYTITLE: | + | {{DISPLAYTITLE:TS-125/AP}} |
Latest revision as of 16:43, 13 June 2018
Contents
Overview
Power Meter TS-125/AP is a compact, lightweight, battery-operated, UHF wattmeter used in checking the relative power output or radar transmitters. It may also be employed in measuring antenna radiation patterns and standing wave ratios. This equipment consists of a temperature-compensated thermistor bridge, a milliwattmeter, and a horn-type pickup antenna.
Relationship to Similar Equipment
This equipment is part of Test Set AN~APM-33, Test Set AN~MPM-2, and Test Kit AN/UPM1-7. Equipment Required But -Not Supplied: Battery: (3) BA-30.
Technical Description
- Power Requirements
- 4.5 v dc
- Frequency Range
- 2,400 to 3,335 mc
- Type of Emission
- CW, pulse
- Power Range
- 0 to 2 mw, 0 to 4 w (with attenuators); above 4 w (with pickup ant).
- Temperature Range
- -20° C to +60° C
- Accuracy
- ±.5 db
- Major Units
- TS125/AP 10" x 7 7/8" x 5 5/16"; 12 lbs
Reference Data and Literature
- TM 11-1217
- Army Spec 71-5067