Difference between revisions of "User:BinD"
Jump to navigation
Jump to search
Line 52: | Line 52: | ||
* [[I-49]] Part of [[IE-10]] Portable decade type Wheatstone Bridge for use of wire chief, line repairmen and maintenance man. For maintaining open wire and field wire circuits, and short haul cable circuits in small offices only, and for location of grounds, crosses, and shorts. Cannot readily be used for open location and capacitance measurements. Requires use of 3 batteries BA-30. | * [[I-49]] Part of [[IE-10]] Portable decade type Wheatstone Bridge for use of wire chief, line repairmen and maintenance man. For maintaining open wire and field wire circuits, and short haul cable circuits in small offices only, and for location of grounds, crosses, and shorts. Cannot readily be used for open location and capacitance measurements. Requires use of 3 batteries BA-30. | ||
* [[I-50]] Voltammeter Part of [[IE-29]] DC, triple range, scale ranges 0-3, 0-15, 0-150 volts and 0-3, 0-15 and 0-30 amperes. | * [[I-50]] Voltammeter Part of [[IE-29]] DC, triple range, scale ranges 0-3, 0-15, 0-150 volts and 0-3, 0-15 and 0-30 amperes. | ||
− | * [[I-51]] | + | * [[I-51]] Test Set Part of [[IE-29]] Cable repairman's portable tone test set, for locating shorts, grounds, crosses, split pairs and wet spots in cables. Consists of a tone supply from a spark gap induction coil. Includes an exploring coil (W.E.Co. 19C Test Set) and receiver, cord and plug all of which comprise W.E.Co. l0l9C Test Set. Has high output and therefore will introduce noise in parallel circuits. Requires 4 Batteries BA-23. |
* [[I-52]] | * [[I-52]] | ||
* [[I-53]] | * [[I-53]] | ||
* [[I-54]] | * [[I-54]] | ||
* [[I-55]] | * [[I-55]] | ||
− | * [[I-56]] | + | * [[I-56]] Test Set Part of [[IE-26]] A universal radio test set. Consists of a group of instruments for servicing radio equipment; output meter, tube tester, meters for measuring current, voltage and resistance In various ranges, in carrying case. |
* [[I-57]] | * [[I-57]] | ||
* [[I-58]] | * [[I-58]] |
Revision as of 16:15, 16 April 2014
hi and stuff I / Instruments
- I-1 Compass type
- I-2 Voltmeter
- I-3 Voltmeter
- I-4 Ammeter
- I-5 Voltmeter
- I-6 Voltmeter
- I-7 Ammeter
- I-8 Ammeter
- I-9 Ammeter
- I-10 Voltmeter
- I-11 Ammeter
- I-12 Ammeter
- I-13 Voltmeter
- I-14 Compass
- I-15 Clock
- I-16 Indicator
- I-17 Voltmeter
- I-18 Voltmeter
- I-19 Ammeter
- I-20 Ammeter
- I-21 Voltmeter
- I-22 Ammeter
- I-23 Volt-ammeter, Part of IE-29 Small meter for battery testing; scale ranges, 0-35 amp, and 0-11 volts; with 10 in, cord.
- I-24 Compass
- I-25 ?
- I-26 Voltmeter
- I-27 Voltmeter
- I-28 Polarity Indicator
- I-29 Ammeter
- I-30 Watch
- I-31 Clock
- I-32 Clock
- I-33 Stop Watch
- I-34 Controller
- I-35 Galvanometer
- I-36 Ohmeter
- I-37 Compass
- I-38 Galvanometer
(NOTE 1920 storage catalog ends here)
- I-39
- I-40
- I-41
- I-42
- I-43
- I-44
- I-45
- I-46
- I-47
- I-48 Part of TE-56-A For measuring resistance 0-1000 megaohms. 500 volt. Single range. “Megger”
- I-49 Part of IE-10 Portable decade type Wheatstone Bridge for use of wire chief, line repairmen and maintenance man. For maintaining open wire and field wire circuits, and short haul cable circuits in small offices only, and for location of grounds, crosses, and shorts. Cannot readily be used for open location and capacitance measurements. Requires use of 3 batteries BA-30.
- I-50 Voltammeter Part of IE-29 DC, triple range, scale ranges 0-3, 0-15, 0-150 volts and 0-3, 0-15 and 0-30 amperes.
- I-51 Test Set Part of IE-29 Cable repairman's portable tone test set, for locating shorts, grounds, crosses, split pairs and wet spots in cables. Consists of a tone supply from a spark gap induction coil. Includes an exploring coil (W.E.Co. 19C Test Set) and receiver, cord and plug all of which comprise W.E.Co. l0l9C Test Set. Has high output and therefore will introduce noise in parallel circuits. Requires 4 Batteries BA-23.
- I-52
- I-53
- I-54
- I-55
- I-56 Test Set Part of IE-26 A universal radio test set. Consists of a group of instruments for servicing radio equipment; output meter, tube tester, meters for measuring current, voltage and resistance In various ranges, in carrying case.
- I-57
- I-58
- I-59
- I-60
- I-61
- I-62
- I-63
- I-64
- I-65
- I-66
- I-67
- I-68
- I-69
- I-70
- I-71
- I-72
- I-73
- I-74
- I-75
- I-76
- I-77
- I-78
- I-79
- I-80
- I-81
- I-82
- I-83
- I-84
- I-85
- I-86
- I-87
- I-88
- I-89
- I-90
- I-91
- I-92
- I-93
- I-94
- I-95
- I-96
- I-97
- I-98
- I-99
- I-100
- vehicle shown is T-4 Armored car. Circa-1933
- Reciever shown is BC-189
Related Files
- Remote Control Equipment
- RC-261
- 28 Oct. 1944