Difference between revisions of "User:BinD"
Jump to navigation
Jump to search
Line 127: | Line 127: | ||
* [[I-124]] | * [[I-124]] | ||
* [[I-125]] | * [[I-125]] | ||
− | * [[I-126]] | + | * [[I-126]] Signal generator Part of IE- Test instrument designed to furnish a signal of desired radio frequency, used for alignment of radio receivers. Band A: 15-25 megacycles. Band B: 195-225 megacycles. |
* [[I-127]] | * [[I-127]] | ||
* [[I-128]] | * [[I-128]] | ||
− | * [[I-129]] | + | * [[I-129]] Frequency meter set Part of [[IE-9]] Consists of four absorption type wave meters contained in a steel carrying case. Frequency range l.5 to 40 mc. |
− | * [[I-130]] | + | * [[I-130]] Signal Generator Part of [[IE-19]] Portable frequency band 100-156 megacycles. Uses separate battery supply. Requires 6 Batteries BA-2 and 4 Batteries BA-23. For tuning Radio Receiver [[BC-624]] and Radio Transmitter [[BC-625]]. |
* [[I-131]] | * [[I-131]] | ||
* [[I-132]] | * [[I-132]] |
Revision as of 16:40, 16 April 2014
hi and stuff I / Instruments
- I-1 Compass type
- I-2 Voltmeter
- I-3 Voltmeter
- I-4 Ammeter
- I-5 Voltmeter
- I-6 Voltmeter
- I-7 Ammeter
- I-8 Ammeter
- I-9 Ammeter
- I-10 Voltmeter
- I-11 Ammeter
- I-12 Ammeter
- I-13 Voltmeter
- I-14 Compass
- I-15 Clock
- I-16 Indicator
- I-17 Voltmeter
- I-18 Voltmeter
- I-19 Ammeter
- I-20 Ammeter
- I-21 Voltmeter
- I-22 Ammeter
- I-23 Volt-ammeter, Part of IE-29 Small meter for battery testing; scale ranges, 0-35 amp, and 0-11 volts; with 10 in, cord.
- I-24 Compass
- I-25 ?
- I-26 Voltmeter
- I-27 Voltmeter
- I-28 Polarity Indicator
- I-29 Ammeter
- I-30 Watch
- I-31 Clock
- I-32 Clock
- I-33 Stop Watch
- I-34 Controller
- I-35 Galvanometer
- I-36 Ohmeter
- I-37 Compass
- I-38 Galvanometer
(NOTE 1920 storage catalog ends here)
- I-39
- I-40
- I-41
- I-42
- I-43
- I-44
- I-45
- I-46
- I-47
- I-48 Part of TE-56-A For measuring resistance 0-1000 megaohms. 500 volt. Single range. “Megger”
- I-49 Part of IE-10 Portable decade type Wheatstone Bridge for use of wire chief, line repairmen and maintenance man. For maintaining open wire and field wire circuits, and short haul cable circuits in small offices only, and for location of grounds, crosses, and shorts. Cannot readily be used for open location and capacitance measurements. Requires use of 3 batteries BA-30.
- I-50 Voltammeter Part of IE-29 DC, triple range, scale ranges 0-3, 0-15, 0-150 volts and 0-3, 0-15 and 0-30 amperes.
- I-51 Test Set Part of IE-29 Cable repairman's portable tone test set, for locating shorts, grounds, crosses, split pairs and wet spots in cables. Consists of a tone supply from a spark gap induction coil. Includes an exploring coil (W.E.Co. 19C Test Set) and receiver, cord and plug all of which comprise W.E.Co. l0l9C Test Set. Has high output and therefore will introduce noise in parallel circuits. Requires 4 Batteries BA-23.
- I-52
- I-53
- I-54
- I-55
- I-56 Test Set Part of IE-26 A universal radio test set. Consists of a group of instruments for servicing radio equipment; output meter, tube tester, meters for measuring current, voltage and resistance In various ranges, in carrying case.
- I-57
- I-58
- I-59
- I-60
- I-61 Test set Part of IE-10 and IE-29 Transmission measuring set; portable, dry battery operation. To measure losses or gains in circuits or apparatus, Includes 1000-cycle oscillator, receiving amplifier, rectifier and meter. Oscillator has outputs -40, -20, and 0 dbm into a 600 ohm load. Will measure power from a 600-ohm source between -50 and +15 dbm over a frequency range from 100 to 10,000 cycles. No spare tubes included, Requires 5 Batteries BA-30 and 3 Batteries BA-56.
- I-62
- I-63
- I-64
- I-65
- I-66
- I-67
- I-68
- I-69
- I-70
- I-71
- I-72 Signal generator Part of IE-9 and IE-26 Self-containing; for operating on a 105-130 volts, 60 cycle (3F3852.1) or 25 cycle (3F3852.2), single phase power Frequency range 100-32.000 kc, with provisions for 400-cycle modulation. Intended for vehicular use.
- I-73
- I-74
- I-75
- I-76 Test set Part of IE-26 Test Oscillator BC-276 with tubes and batteries, test indicator BE-67 with batteries and cords and headset HS-23. Replaces I-66. For aligning marker beacon receivers.
- I-77
- I-78
- I-79
- I-80
- I-81
- I-82
- I-83 Test set Part of IE-9 (alternate) Dynamotor test set; for measuring input current and voltage, output current and voltage and input and output ripple voltage of various 12 and 28 volt dynamotors and dynamotor units. Includes socket and cords.
- I-84
- I-85
- I-86
- I-87
- I-88
- I-89
- I-90
- I-91
- I-92
- I-93
- I-94
- I-95 Field Strength meter Part of IE-12 and IE-19 For determining relative field strength readings and a rough over-all check of transmitter operation, Tube VT-172 ( JAN-1S5) supplied separately. Requires 2 Batteries BA-5 and 1 BA-23
- I-96 Signal Generator Part of IE-12 Provides signals for testing radio receivers and measuring equipment for metering the transmitter output , Includes milliammeter. For tuning and aligning BC-684 receiver and BC-625 transmitter
- I-97 Bias Meter Part of EE-97 and EE-98 Portable field meter of the zero center type, used with Line Unit BE-77 for normal adjustment of teletypewriter circuits. Not required with BE-77-A or -B.
- I-98
- I-99
- I-100
- I-101
- I-102
- I-103
- I-104
- I-105
- I-106
- I-107 Voltohmmeter Part of ME-13 Vacuum tube, dc, battery operated; ranges 0,1 to 10 megohms in 6 steps, 3 to 1000 volts full scale in 6 steps; input resistance 10 megohms on all voltage scales. Requires 5 Batteries BA-30 and 1 Battery BA-40.
- I-108
- I-109
- I-110
- I-111
- I-112
- I-113
- I-114
- I-115
- I-116
- I-117
- I-118
- I-119
- I-120
- I-121
- I-122
- I-123
- I-124
- I-125
- I-126 Signal generator Part of IE- Test instrument designed to furnish a signal of desired radio frequency, used for alignment of radio receivers. Band A: 15-25 megacycles. Band B: 195-225 megacycles.
- I-127
- I-128
- I-129 Frequency meter set Part of IE-9 Consists of four absorption type wave meters contained in a steel carrying case. Frequency range l.5 to 40 mc.
- I-130 Signal Generator Part of IE-19 Portable frequency band 100-156 megacycles. Uses separate battery supply. Requires 6 Batteries BA-2 and 4 Batteries BA-23. For tuning Radio Receiver BC-624 and Radio Transmitter BC-625.
- I-131
- I-132
- I-133
- I-134
- I-135
- I-136
- I-137
- I-138
- I-139
- I-140
- I-141
- I-142
- I-143
- I-144
- I-145
- I-146
- I-147
- I-148
- I-149
- I-150
- I-151
- I-152
- I-153
- I-154
- I-155
- I-156
- I-157
- I-158
- I-159
- I-160
- I-161
- I-162
- I-163
- I-164
- I-165
- I-166
- I-167
- I-168
- I-169
- I-170
- I-171
- I-172
- I-173
- I-174
- I-175
- I-176
- I-177
- I-178
- I-179
- I-180
- I-181
- I-182
- I-183
- I-184
- I-185
- I-186
- I-187
- I-188
- I-189
- I-190
- I-191
- I-192
- I-193
- I-194
- I-195
- I-196
- I-197
- I-198
- I-199
- I-200
- vehicle shown is T-4 Armored car. Circa-1933
- Reciever shown is BC-189
Related Files
- Remote Control Equipment
- RC-261
- 28 Oct. 1944