Calibrator I-189-A is a range calibrator for pulse-triggered range oscilloscopes. The oscilloscope sweep is triggered at approximately 480 cycles per second (cps), and the range is calibrated by direct comparison with 500-yard calibration markers. The unit is a portable, self-contained instrument. It contains a crystal-controlled, 327.80-kilocycle (kc) oscillator which furnishes the 500-yard markers and the 480 cps synchronising pulse outputs. Two coaxial cables for connecting the instrument to the set to be calibrated are provided.
 +
[[File:I-189-A.jpg]]
 +
 
==References==
 
==References==
 
* {{pdf|TM 11-1227 1945.pdf|TM 11-1227 May 1945}}
 
* {{pdf|TM 11-1227 1945.pdf|TM 11-1227 May 1945}}

Latest revision as of 18:56, 30 November 2015

Calibrator I-189-A is a range calibrator for pulse-triggered range oscilloscopes. The oscilloscope sweep is triggered at approximately 480 cycles per second (cps), and the range is calibrated by direct comparison with 500-yard calibration markers. The unit is a portable, self-contained instrument. It contains a crystal-controlled, 327.80-kilocycle (kc) oscillator which furnishes the 500-yard markers and the 480 cps synchronising pulse outputs. Two coaxial cables for connecting the instrument to the set to be calibrated are provided. I-189-A.jpg

References

Adobe PDF icon.png TM 11-1227 May 1945