| + | The receiver is a general purpose receiver for use in both fixed and mobile applications. the receiver provides reception of continuous wave (CW) , modulated-continuous wave (MCW), amplitude modulated (AM) frequency shift keyed (FSK) and single sideband (SSB) signals. | ||
| + | |||
| + | |||
| + | ==Technical Details== | ||
| + | ;Frequency Range | ||
| + | :0.5 to 32 mHz | ||
| + | ;Type of Signals Received | ||
| + | :CS, MCS, Voice, SSB, FSK | ||
| + | ;Type of Tuning | ||
| + | :Continuous; frequency read directly on counter type indicator. | ||
| + | ;Method of Calibration | ||
| + | :Built in Crystal-controlled | ||
| + | ;Calibration Points | ||
| + | :Every 100 kHz | ||
| + | ;Power Source | ||
| + | :115 or 230 Volts AC +-10% | ||
| + | ;Power Output | ||
| + | :250 Watts Total; 140 watts with OVENS switch turned to OFF | ||
| + | |||
| + | |||
| + | ==Images== | ||
[[File:R-390A-URR.jpg||400px]] | [[File:R-390A-URR.jpg||400px]] | ||
| − | + | [[File:R-390A-URR-1.png]] | |
Revision as of 12:46, 4 June 2013
The receiver is a general purpose receiver for use in both fixed and mobile applications. the receiver provides reception of continuous wave (CW) , modulated-continuous wave (MCW), amplitude modulated (AM) frequency shift keyed (FSK) and single sideband (SSB) signals.
Technical Details
- Frequency Range
- 0.5 to 32 mHz
- Type of Signals Received
- CS, MCS, Voice, SSB, FSK
- Type of Tuning
- Continuous; frequency read directly on counter type indicator.
- Method of Calibration
- Built in Crystal-controlled
- Calibration Points
- Every 100 kHz
- Power Source
- 115 or 230 Volts AC +-10%
- Power Output
- 250 Watts Total; 140 watts with OVENS switch turned to OFF