Amplifier Alignment Test Set
 
Amplifier Alignment Test Set
 +
* Amplifier Alignment Unit TS-92/AP is a class
 +
A special test equipment used in aligning the amplifier
 +
stages of radar jamming transmitters. It can be used with
 +
Transmitting Equipment AN/APT- 1, Radio Set AN/ARQ-8.
 +
Using the TS-92/AP the amplifier of the transmitter may
 +
be adjusted to give optimum performance at any band width
 +
between0.5to 7 mc. for any carrier frequency in the range
 +
from 15-250 mc. This simple device is intended for use
 +
in the field where more elaborate equipment, such as oscilloscope and sweep oscillator, is not available. It consists essentially of a radio receiver designed in such a
 +
way that the two peaks in the amplifier response curve may
 +
be maximized to give optimum adjustment of the amplifier.
 +
Power is obtained from a-115volt 60-2600 c.p.s.,
 +
a.c. power source. A one-tenth volt input gives full scale
 +
meter indication.
 +
Army Supply Program requirements as of 10
 +
November 1944 were 660 equipments for the calendar year
 +
1944 and 1,667 for 1945.
  
 
[[File:TS-92-AP.jpeg|500px]]
 
[[File:TS-92-AP.jpeg|500px]]
 +
 +
==Components==
 +
* TS-92
 +
* [[AS-142]] loop probe
 +
* [[AS-122]] antenna probe
 +
* [[CG-69]] cord
 +
* [[CG-153]] cord
  
 
==References==
 
==References==
 
* none found
 
* none found

Revision as of 19:35, 23 March 2025

Amplifier Alignment Test Set

  • Amplifier Alignment Unit TS-92/AP is a class

A special test equipment used in aligning the amplifier stages of radar jamming transmitters. It can be used with Transmitting Equipment AN/APT- 1, Radio Set AN/ARQ-8. Using the TS-92/AP the amplifier of the transmitter may be adjusted to give optimum performance at any band width between0.5to 7 mc. for any carrier frequency in the range from 15-250 mc. This simple device is intended for use in the field where more elaborate equipment, such as oscilloscope and sweep oscillator, is not available. It consists essentially of a radio receiver designed in such a way that the two peaks in the amplifier response curve may be maximized to give optimum adjustment of the amplifier. Power is obtained from a-115volt 60-2600 c.p.s., a.c. power source. A one-tenth volt input gives full scale meter indication. Army Supply Program requirements as of 10 November 1944 were 660 equipments for the calendar year 1944 and 1,667 for 1945.

TS-92-AP.jpeg

Components

References

  • none found