Overview

Decibel Meter ME-22/PCM is a portable, amplifier-rectifier type output power measuring unit used in testing wire and wire-radio communication circuits.


ME-22 PCM.png


Relationship to Similar Equipment

This equipment, with the signal generator SG-15/PCM, is part of Telephone Test Set TS-140/PCM.

Technical Description

Power Requirements
50 w, 115 or 230 v ±10%, 50 to 70 cy, 1 phase ac
Frequency Range
200 to 35,000 cy
Impedance
600 ohms; 8,000 ohms
Meter Range
-45 to +25 dbm
Accuracy
± .5 db
Major Unit
ME-22/PMC 7" x 19" x 10 7/8"'; 37 lbs


Tubes, Crystals, Transistors

  • 1 - OC3
  • 1 - 5Y3GT
  • 1 - 6H6
  • 1 - 6L6GAY
  • 3 - 6SJ7
  • 1 - 6SQ7


Reference Data and Literature

  1. TM 11-2096
  2. MIL-T-12643