SB-361

From RadioNerds
Revision as of 18:59, 3 July 2019 by Cdewit (talk | contribs)
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)
Jump to navigation Jump to search

SB-361.TT.jpg


Power Switchboard SB-361/TT was a transportable power panel similar to Panel BD-132A except that it was used with equipment requiring a 24-volt battery supply instead of a 48-volt battery supply. The SB-361 /TT provided ringing current from either a 60-cycle source or the 24-volt central office battery. A rectifier was mounted in the power panel which was used to keep the central office battery charged. Power Switchboard SB-361/TT did not include the night alarm, fuse alarm, or no-voltage alarm circuits that are included in Panels BD-132 and BD-132-A.


Reference File


See Also

BD-132

SB - Switchboards

2000