OVERVIEW
A portable general purpose test panel designed to accurately measure audio volume levels in broadcasting, sound recording, telephone transmission, and allied fields where precise monitoring over the audio range is required.
TECHNICAL DESCRIPTION:
- Circuit Information
- The input circuit consists of a shielded transformer. This is followed by an audio-amplifier, and the indicating meter. A thermal relay shorts out the meter for 20 seconds after power is applied to the built-in regulated supply to avoid damage due to surge voltages.
- Power Supply
- 115 volts ±10%, ac, 50 to 60 cycles per second, single-phase, 15 watts ;Frequency Range:
- 30 to 15,000 cps
- Audio Level Indicating Range
- As a bridging type instrument: -20 to +20 db with a total range including meter scale of -40 to +23 db
- As a terminating type instrument: -40 to +20 db with a total range including meter scale of -60 to +23 db
- Meter Scale
- -20 to +3 dbm
- Reference Level
- 0 VU (1 mw into 600 ohms)
- Input Impedance
- Terminating Connection: 600 ohms
- Bridging Connection: 12,500 ohms
- Frequency Response
- ±0.1 db from 200 to 10,000 cps
- ±0.5 db from 30 to 15,000 cps
- Accuracy
- Overall: ±5%
- From-15 to +10 db from 200 to 10,000 cps. ±1%
- Temperature Range
- -15° C. (+5° F.) to +55°C. (+131° F.)
- Humidity Range
- Up to 90%
- Major Unit
- TS429A/U 5 1/4" x 19" x 11"; 20 lbs
TUBES, CRYSTALS, TRANSISTORS:
- 1 - JAN-6AG7,
- 1 - JAN-6X5GT,
- 1 - JAN-OD3/VR-150

REFERENCE DATA AND LITERATURE:
- NAVSHIPS 91900 (Instruction Book)
- TO 33A1-10-29-1 (Instruction Book)
- MIL-A-17045 (Ships) 21 February 1952