| − | S-250 | + | [[File:S-250 Shelter 8753033108 l.jpg|400px]] |
| − | S-250 (PTT) COMMUNICATION CELL transports and operates base communication equipment with 1 1/4-ton military trucks (M705, M715, and XM561), 1 1/4-ton Type E commercial utility cargo vehicle (CUCV), 1 1/4-ton High Mobility Multipurpose Wheeled Vehicle (HMMWV), military cargo aircraft such as the C-130, helicopter, and by sea or rail unit. This high strength, insulated, all-weather, general purpose unit is designed to meet the user | + | S-250 (PTT) COMMUNICATION CELL transports and operates base communication equipment with 1 1/4-ton military trucks (M37, M705, M715, and XM561), 1 1/4-ton Type E commercial utility cargo vehicle ([[CUCV]]), 1 1/4-ton High Mobility Multipurpose Wheeled Vehicle (HMMWV), military cargo aircraft such as the C-130, helicopter, and by sea or rail unit. This high strength, insulated, all-weather, general purpose unit is designed to meet the user's specifications for complete systems integration. |
The S-250 shelter is a foam and beam bonded sandwich construction consisting of a polyurethane foam core, aluminum skins and a framework of high strength aluminum alloy extrusions. Foam and beam panel construction provides high strength to weight ratios and facilitates ease of modification, repair, and maintenance. | The S-250 shelter is a foam and beam bonded sandwich construction consisting of a polyurethane foam core, aluminum skins and a framework of high strength aluminum alloy extrusions. Foam and beam panel construction provides high strength to weight ratios and facilitates ease of modification, repair, and maintenance. | ||
| − | |||
| − | Performance Specifications | + | ==Performance Specifications== |
| − | Specification MIL-S-55541 | + | ;Specification |
| + | :MIL-S-55541 | ||
| − | Weight: | + | ;Weight: |
| − | With EMI kit 762 lbs. min. - 802 lbs. max | + | :With EMI kit 762 lbs. min. - 802 lbs. max |
| − | Without EMI kit 750 lbs. min. - 790 lbs. max | + | :Without EMI kit 750 lbs. min. - 790 lbs. max |
| − | Payload: 2,530 lbs. | + | ;Payload: |
| + | :2,530 lbs. | ||
| − | Roof Load: | + | ;Roof Load: |
| − | Snow and Ice 40 lbs./sq. ft. | + | :Snow and Ice 40 lbs./sq. ft. |
| − | + | :personnel and Equipment - 660 lbs. over a 2 sq. ft. area. | |
| − | Floor Load: 1,000 lbs. over 3 sq. ft. area without permanent deformation | + | ;Floor Load: |
| + | :1,000 lbs. over 3 sq. ft. area without permanent deformation | ||
| − | Member Loading: Wall, roof, and floor tensile load 1,000 lbs. followed by 75 inch-pounds torque load 5/16"-18 inserts | + | ;Member Loading: |
| + | :Wall, roof, and floor tensile load 1,000 lbs. followed by 75 inch-pounds torque load 5/16"-18 inserts | ||
| − | Temperature Extremes: | + | ;Temperature Extremes: |
| − | Operating: -65° F to +125° F plus solar load | + | :Operating: -65° F to +125° F plus solar load |
| − | Non-operating: -80° F to +160° F | + | :Non-operating: -80° F to +160° F |
| − | Heat Tranfer: U-factor - 0.50BTU/hr./sq. ft./° F. Designed to meet requirements of MIL-S-55541 | + | ;Heat Tranfer: |
| + | :U-factor - 0.50BTU/hr./sq. ft./° F. Designed to meet requirements of MIL-S-55541 | ||
| − | RFI Shielding: With addition of RFI modification kit, attenuation of 60 dB minimum over 150 kHz to 10 GHz for electric and magnetic fields and plane waves measured IAW MIL-STD-285 | + | ;RFI Shielding: |
| + | :With addition of RFI modification kit, attenuation of 60 dB minimum over 150 kHz to 10 GHz for electric and magnetic fields and plane waves measured IAW MIL-STD-285 | ||
| − | Watertightness: Tested to 30 inch fording depth and to simulated rainfall | + | ;Watertightness: |
| + | :Tested to 30 inch fording depth and to simulated rainfall | ||
| − | Lifting Eyes: Four (4) eyes with 3 in. inside clearance. 5,000 lbs. tensile load per corner in any direction | + | ;Lifting Eyes: |
| + | :Four (4) eyes with 3 in. inside clearance. 5,000 lbs. tensile load per corner in any direction | ||
| + | |||
| + | ;Towing Eyes: | ||
| + | :Four (4) eyes with 1.50 in. inside clearance. 5,000 lbs. tensile load per corner in any direction | ||
| + | |||
| + | |||
| + | ==Reference Files== | ||
| + | |||
| + | ;{{pdf|TB10-5411-205-23.PDF|TB10-5411-205-23}} | ||
| + | :WARRANTY PROGRAM | ||
| + | ::ELECTRICAL EQUIPMENT SHELTERS | ||
| + | ::MODEL S-250/G UNSHIELDED (NSN: 5411-00-999-4935) | ||
| + | ::MODEL S-250/G SHIELDED (NSN: 5411-00-489-6076) | ||
| + | ::31 JANUARY 1990 | ||
| − | |||
[[Category:Military/Shelters]] | [[Category:Military/Shelters]] | ||
Latest revision as of 16:16, 18 October 2025
S-250 (PTT) COMMUNICATION CELL transports and operates base communication equipment with 1 1/4-ton military trucks (M37, M705, M715, and XM561), 1 1/4-ton Type E commercial utility cargo vehicle (CUCV), 1 1/4-ton High Mobility Multipurpose Wheeled Vehicle (HMMWV), military cargo aircraft such as the C-130, helicopter, and by sea or rail unit. This high strength, insulated, all-weather, general purpose unit is designed to meet the user's specifications for complete systems integration.
The S-250 shelter is a foam and beam bonded sandwich construction consisting of a polyurethane foam core, aluminum skins and a framework of high strength aluminum alloy extrusions. Foam and beam panel construction provides high strength to weight ratios and facilitates ease of modification, repair, and maintenance.
Performance Specifications
- Specification
- MIL-S-55541
- Weight
- With EMI kit 762 lbs. min. - 802 lbs. max
- Without EMI kit 750 lbs. min. - 790 lbs. max
- Payload
- 2,530 lbs.
- Roof Load
- Snow and Ice 40 lbs./sq. ft.
- personnel and Equipment - 660 lbs. over a 2 sq. ft. area.
- Floor Load
- 1,000 lbs. over 3 sq. ft. area without permanent deformation
- Member Loading
- Wall, roof, and floor tensile load 1,000 lbs. followed by 75 inch-pounds torque load 5/16"-18 inserts
- Temperature Extremes
- Operating: -65° F to +125° F plus solar load
- Non-operating: -80° F to +160° F
- Heat Tranfer
- U-factor - 0.50BTU/hr./sq. ft./° F. Designed to meet requirements of MIL-S-55541
- RFI Shielding
- With addition of RFI modification kit, attenuation of 60 dB minimum over 150 kHz to 10 GHz for electric and magnetic fields and plane waves measured IAW MIL-STD-285
- Watertightness
- Tested to 30 inch fording depth and to simulated rainfall
- Lifting Eyes
- Four (4) eyes with 3 in. inside clearance. 5,000 lbs. tensile load per corner in any direction
- Towing Eyes
- Four (4) eyes with 1.50 in. inside clearance. 5,000 lbs. tensile load per corner in any direction
Reference Files
- WARRANTY PROGRAM
- ELECTRICAL EQUIPMENT SHELTERS
- MODEL S-250/G UNSHIELDED (NSN: 5411-00-999-4935)
- MODEL S-250/G SHIELDED (NSN: 5411-00-489-6076)
- 31 JANUARY 1990