Difference between revisions of "S-250"

From RadioNerds
Jump to navigation Jump to search
 
(One intermediate revision by one other user not shown)
Line 1: Line 1:
 
[[File:S-250 Shelter 8753033108 l.jpg|400px]]
 
[[File:S-250 Shelter 8753033108 l.jpg|400px]]
  
S-250 (PTT) COMMUNICATION CELL  transports  and operates base communication equipment with  1 1/4-ton military trucks (M705, M715, and XM561), 1 1/4-ton Type E commercial utility cargo vehicle (CUCV), 1 1/4-ton High Mobility Multipurpose Wheeled Vehicle (HMMWV), military cargo aircraft such as the C-130, helicopter, and by sea or rail unit. This high strength, insulated, all-weather, general purpose unit is designed to meet the user's specifications for complete systems integration.
+
S-250 (PTT) COMMUNICATION CELL  transports  and operates base communication equipment with  1 1/4-ton military trucks (M705, M715, and XM561), 1 1/4-ton Type E commercial utility cargo vehicle ([[CUCV]]), 1 1/4-ton High Mobility Multipurpose Wheeled Vehicle (HMMWV), military cargo aircraft such as the C-130, helicopter, and by sea or rail unit. This high strength, insulated, all-weather, general purpose unit is designed to meet the user's specifications for complete systems integration.
  
 
The S-250 shelter is a foam and beam bonded sandwich construction consisting of a polyurethane foam core, aluminum skins and a framework of high strength aluminum alloy extrusions. Foam and beam panel construction provides high strength to weight ratios and facilitates ease of modification, repair, and maintenance.
 
The S-250 shelter is a foam and beam bonded sandwich construction consisting of a polyurethane foam core, aluminum skins and a framework of high strength aluminum alloy extrusions. Foam and beam panel construction provides high strength to weight ratios and facilitates ease of modification, repair, and maintenance.
Line 45: Line 45:
 
;Towing Eyes:  
 
;Towing Eyes:  
 
:Four (4) eyes with 1.50 in. inside clearance. 5,000 lbs. tensile load per corner in any direction
 
:Four (4) eyes with 1.50 in. inside clearance. 5,000 lbs. tensile load per corner in any direction
 +
 +
 +
===Reference Files===
 +
 +
;{{pdf|TB10-5411-205-23.PDF|TB10-5411-205-23}}
 +
:WARRANTY PROGRAM
 +
::ELECTRICAL EQUIPMENT SHELTERS
 +
::MODEL S-250/G UNSHIELDED (NSN: 5411-00-999-4935)
 +
::MODEL S-250/G SHIELDED (NSN: 5411-00-489-6076)
 +
::31 JANUARY 1990
 +
  
  
 
[[Category:Military/Shelters]]
 
[[Category:Military/Shelters]]

Latest revision as of 17:55, 1 May 2016

S-250 Shelter 8753033108 l.jpg

S-250 (PTT) COMMUNICATION CELL transports and operates base communication equipment with 1 1/4-ton military trucks (M705, M715, and XM561), 1 1/4-ton Type E commercial utility cargo vehicle (CUCV), 1 1/4-ton High Mobility Multipurpose Wheeled Vehicle (HMMWV), military cargo aircraft such as the C-130, helicopter, and by sea or rail unit. This high strength, insulated, all-weather, general purpose unit is designed to meet the user's specifications for complete systems integration.

The S-250 shelter is a foam and beam bonded sandwich construction consisting of a polyurethane foam core, aluminum skins and a framework of high strength aluminum alloy extrusions. Foam and beam panel construction provides high strength to weight ratios and facilitates ease of modification, repair, and maintenance.


Performance Specifications

Specification
MIL-S-55541
Weight
With EMI kit 762 lbs. min. - 802 lbs. max
Without EMI kit 750 lbs. min. - 790 lbs. max
Payload
2,530 lbs.
Roof Load
Snow and Ice 40 lbs./sq. ft.
personnel and Equipment - 660 lbs. over a 2 sq. ft. area.
Floor Load
1,000 lbs. over 3 sq. ft. area without permanent deformation
Member Loading
Wall, roof, and floor tensile load 1,000 lbs. followed by 75 inch-pounds torque load 5/16"-18 inserts
Temperature Extremes
Operating: -65° F to +125° F plus solar load
Non-operating: -80° F to +160° F
Heat Tranfer
U-factor - 0.50BTU/hr./sq. ft./° F. Designed to meet requirements of MIL-S-55541
RFI Shielding
With addition of RFI modification kit, attenuation of 60 dB minimum over 150 kHz to 10 GHz for electric and magnetic fields and plane waves measured IAW MIL-STD-285
Watertightness
Tested to 30 inch fording depth and to simulated rainfall
Lifting Eyes
Four (4) eyes with 3 in. inside clearance. 5,000 lbs. tensile load per corner in any direction
Towing Eyes
Four (4) eyes with 1.50 in. inside clearance. 5,000 lbs. tensile load per corner in any direction


Reference Files

Adobe PDF icon.png TB10-5411-205-23

WARRANTY PROGRAM
ELECTRICAL EQUIPMENT SHELTERS
MODEL S-250/G UNSHIELDED (NSN: 5411-00-999-4935)
MODEL S-250/G SHIELDED (NSN: 5411-00-489-6076)
31 JANUARY 1990