Wattmeter AN/URM-120 (figure 1-1) is designed to measure incident and reflected r-f power from 10 to 1000 watts within a frequency range of 2 to 1000 mc. Three coupler-detectors, each rated to cover a portion of this frequency range are supplied with the wattmeter.
Coupler Detector Characteristics | ||||
---|---|---|---|---|
Insertion VSWR (Max value with type-N connectors on primary line) | ||||
Model No. | Freq Range (mHz) | Power Range(Watts) | Lowest Power Range | 3 Highest Power Ranges |
CU-753/URM-120 | 2-30 | 50, 100, 500, 1000 | 1.08 | 1.08 |
CU-754/URM-120 | 25-250 | 10, 50, 100, 500 | 1.08 | 1.05 |
CU-755/URM-120 | 200-1000 | 10, 50, 100, 500 | 1.08 | 1.05 |