Difference between revisions of "PL - Plug"

From RadioNerds
Jump to navigation Jump to search
 
(46 intermediate revisions by the same user not shown)
Line 1: Line 1:
* [[Pl-1]] 2-conductor, service buzzer [[EE-63]]
+
==notes==
* [[PL-2]] 3-conductor,  JK-15
+
On the connectors, writing an explanation that would allow anyone to understand the nomenclature system would take all day and I'd probably miss something anyway. So I'll abbreviate it.
 +
 
 +
 
 +
The full nomenclature of most of the large banana pin style cable connectors with the push-button lock (as opposed to an Acme thread nut) is as follows:
 +
 
 +
* PL-xnn where "nn" is a 2-digit number and "x" is"
 +
* P = straight back shell with solder gland
 +
* Q = right-angle back shell with solder gland
 +
* R = right angle back shell with cable clamp or straight back shell with right-angle cable clamp
 +
* S = straight back shell with cable clamp
 +
 
 +
The PL-103 only came in P and Q. Some other plugs (but not these five) had only PL-nn nomenclature.
 +
 
 +
For whatever reason, the aircraft installations usually use solder gland types and vehicular installations usually use cable clamps. We don't actually know what they would have used for an aircraft set installed in a vehicle, but I would bet on cable clamp and rubber jacketed cable, which is in any case much easier to either simulate or duplicate. So making that assumption, the actual nomenclature of the connectors that you need to put an SCR-187 into the T-36 are:
 +
 
 +
PL-S59 x 2, PL-S61 x 2, PL-S64 plus whatever the other end needs, PL-S74 plus whatever the other end needs, and PL-S103 or PL-Q103. If you stack the receiver on top of the transmitter, PL-Q103 will probably work better as on it, the cable drops out the bottom rather than sticking out the back.
 +
 
 +
That being said, most sellers on eBay or elsewhere won't know all of this and will just refer to them as PL-59, PL-61, etc. You'll have to look at the photos to tell what they are really selling.
 +
 
 +
Yes, PL is a cable plug. No, PLS doesn't mean anything. The mating chassis connector will have a nomenclature of SO-nn. The plug in the back of the BC-224 is SO-104, despite the fact that it is male.
 +
 
 +
If you cannot find them closer by, I can supply the PL-S59 through PL-S64 but only with the modified Romex cable clamp. When you make up your mind whether to stack the radios or not and can then decide whether straight or right angle PL-x103 will work best, I am supposed to have one PL-Q103 (if I can locate it) that I would swap even for the PL-P103 you have.
 +
 
 +
The manual I took the two photos out of does not have one showing cables coming out of the BC-191. I'll try to find one, or take a picture of one of the connectors and post it.
 +
 
 +
Right now, I have to get back to scanning NAVAER 08-5Q-95 for an order I accepted. I thought I had done the scanning ten years or so ago, didn't, but still have to ship.
 +
Gunner
 +
USNR Retired
 +
MVPA 9480
 +
 
 +
==List==
 +
* [[PL-1]] 2-conductor, service buzzer [[EE-63]]
 +
* [[PL-2]] 3-conductor,  [[JK-15]]
 
* [[PL-3]] ?
 
* [[PL-3]] ?
 
* [[PL-4]] ?
 
* [[PL-4]] ?
* [[PL-5]] Audio Plug U/W JK-14,29,39    P/O [[P-11]], Key [[J-40]], CD-56
+
* [[PL-5]] Audio Plug U/W [[JK-14]],29,39    P/O [[P-11]], Key [[J-40]], [[CD-56]]
 
* [[PL-6]] two terminal, WEco. No. 156
 
* [[PL-6]] two terminal, WEco. No. 156
 
* [[PL-7]] two terminal,
 
* [[PL-7]] two terminal,
* [[PL-8]] two terminal, WEco. No. 158 Plug U/W JK-7
+
* [[PL-8]] two terminal, WEco. No. 158 Plug U/W [[JK-7]]
 
* [[PL-9]] four terminal, WEco. No. 164
 
* [[PL-9]] four terminal, WEco. No. 164
 
* [[PL-10]] four terminal, WEco. No. 160
 
* [[PL-10]] four terminal, WEco. No. 160
* [[PL-11]] ?
+
* [[PL-11]], switchboard plug, [[JK-47]], [[EE-2]], [[SCR-134]]
 
* [[PL-12]] single terminal, WEco. No. 159
 
* [[PL-12]] single terminal, WEco. No. 159
 
* [[PL-13]] same as PL-8 but without screw eye.
 
* [[PL-13]] same as PL-8 but without screw eye.
* [[PL-14]] polarity, 2 single terminal plug bodies, mounted in a bakelight block. fits JK-5.
+
* [[PL-14]] polarity, 2 single terminal plug bodies, mounted in a bakelight block. fits [[JK-6]].
* [[PL-15]] four single terminal plug bodies, mounted in two hard rubber blocks,  for CD-24 cord, [[BC-13]], WEco. No. 162
+
* [[PL-15]] four single terminal plug bodies, mounted in two hard rubber blocks,  for [[CD-24]] cord, [[BC-13]], WEco. No. 162
* [[PL-16]]
+
* [[PL-16]] telephone, copy of french type,
* [[PL-17]]
+
* [[PL-17]], black dilecto block, double spring pins, 4-Volt
* [[PL-18]]
+
* [[PL-18]], same as 17 except 10-Volt
* [[PL-19]]
+
* [[PL-19]], same as 17 but marked amplifier
* [[PL-20]]
+
* [[PL-20]], same as 17 but marked telephone.
* [[PL-21]]
+
* [[PL-21]], 2 terminal mounted between fiber blocks, [[EE-14]]
* [[PL-22]]
+
* [[PL-22]], 2 conductor, two pin, in hard rubber block, [[CD-81]], and [[CD-34]]
* [[PL-23]]
+
* [[PL-23]], 2 single terminal plug bodies molded in compound. for [[EE-10]]  
* [[PL-24]]
+
* [[PL-24]], 1 single terminal in hard rubber sleeve, for [[BC-92]]
* [[PL-25]]
+
* [[PL-25]], metal, plug to close hole in pipe ? P/O [[EE-20]]
* [[PL-26]]
+
* [[PL-26]], solid brass, copper plated, with brass thumbpiece. P/O [[BD-15]]
* [[PL-27]]
+
* [[PL-27]], 2 spring bras contact strips, mounted on micarta base. P/O [[BE-11]]
* [[PL-28]]
+
* [[PL-28]], 2 conductor, No.18 coper strips, GE Co. marine outlet No.22323. for target range ?
* [[PL-29]]
+
* [[PL-29]], ??
* [[PL-30]]
+
* [[PL-30]], connecting, telephone, water tight, P/O [[EE-49]] telautograph
* [[PL-31]]
+
* [[PL-31]], connecting, 7-contact, water tight, [[EE-49]]
* [[PL-32]]
+
* [[PL-32]], 2 single contact plug bodies attached to a black fiber handle, for [[SW-62]]
 
(NOTE 1920 storage catalog ends here)
 
(NOTE 1920 storage catalog ends here)
 
* [[PL-33]]
 
* [[PL-33]]
Line 36: Line 68:
 
* [[PL-35]]
 
* [[PL-35]]
 
* [[PL-36]]
 
* [[PL-36]]
* [[PL-37]] 1-cond. U/W SO-14
+
* [[PL-37]] 1-cond. U/W [[SO-14]]
* [[PL-38]] 2-cond. U/W SO-15
+
* [[PL-38]] 2-cond. U/W [[SO-15]]
* [[PL-39]]
+
* [[PL-39]],black,  [[CD-119]], [[SCR-189]]
* [[PL-40]] 4-cond. U/W SO-17
+
* [[PL-40]] 4-cond. U/W [[SO-17]]
* [[PL-41]],    4-cond. U/W SO-18
+
* [[PL-41]],    4-cond. U/W [[SO-18]]
* [[PL-42]] 4-cond. U/W SO-18
+
* [[PL-42]], red, 4-cond. U/W [[SO-18]], [[CD-120]], [[SCR-189]]
* [[PL-43]] 5-cond. U/W SO-19 P/O [[BC-120]], [[BC-121]]
+
* [[PL-43]] 5-cond. U/W [[SO-19]] P/O [[BC-120]], [[BC-121]]
* [[PL-44]] 6-cond. U/W SO-20
+
* [[PL-44]], [[CD-121]], 6-cond. U/W [[SO-20]], [[SCR-189]],
* [[PL-45]] 6-cond. U/W SO-21, JK-34 P/O [[BD-41]]
+
* [[PL-45]] 6-cond. U/W [[SO-21]], [[JK-34]] P/O [[BD-41]]
* [[PL-46]] Phone Plug U/W JK-43 P/O T-11,12
+
* [[PL-46]] Phone Plug U/W [[JK-43]] P/O [[T-11]],12
* [[PL-47]] Phone Plug  U/W [[BD-57]]*, [[BC-726]], JK-24 P/O [[SCR-296]]*
+
* [[PL-47]] Phone Plug  U/W [[BD-57]]*, [[BC-726]], [[JK-24]] P/O [[SCR-296]]*
* [[PL-48]] Phone Plug  S/T PL-55 U/W JK-34
+
* [[PL-48]] Phone Plug  S/T [[PL-55]] U/W [[JK-34]]
* [[PL-50]] 4-cond.  U/W SO-22 P/O CD-103,106,125,203
+
* [[PL-50]] 4-cond.  U/W [[SO-22]] P/O CD-103,106,125,203, [[SCR-178]]
* [[PL-50-A]] S/T PL-50, with clamp
+
* [[PL-50-A]] S/T [[PL-50]], with clamp
* [[PL-51]] 3-way Phone Plug  U/W CC-70, JK-22
+
* [[PL-51]] 3-way Phone Plug  U/W CC-70, [[JK-22]]
* [[PL-54]] Audio Plug U/W JK-20 P/O Headsets [[H-16]]/U, [[H-18]]/U
+
* [[PL-52]]
* [[PL-55]]* 2-cond Telephone Plug U/W J-671, JK-3,28,30,34,39, U-17/GT
+
* [[PL-53]]
* [[PL-56]] 5-cond.  U/W SO-36, M-144 P/O CD-122
+
* [[PL-54]] Audio Plug U/W JK-26 P/O Headsets [[HS-18]], [[HS-23]], [[H-16]]/U, [[H-18]]/U
* [[PL-R56]] S/T PL-56  U/W SO-36
+
* [[PL-55]]* 2-cond Telephone Plug U/W J-671, [[JK-3]],28,30,34,39, U-17/GT
 +
* [[PL-56]] 5-cond.  U/W [[SO-36]], M-144 P/O [[CD-122]]
 +
* [[PL-R56]] S/T PL-56  U/W [[SO-36]]
 
* [[PL-S56]] S/T PL-56 P/O nine CD- Cord Sets
 
* [[PL-S56]] S/T PL-56 P/O nine CD- Cord Sets
 
* [[PL-57]] PL-55 plug with Binding Posts    P/O [[ML-110]] Time Unit
 
* [[PL-57]] PL-55 plug with Binding Posts    P/O [[ML-110]] Time Unit
* [[PL-58]] 3-cond, block plug U/W JK-37, [[BD-70]],71,96 (chest sets)
+
* [[PL-58]] 3-cond, block plug U/W [[JK-37]], [[BD-70]],71,96 (chest sets)
* [[PL-59]] 1 cond, chrome finish U/W SO-39 P/O CD-141, [[BC-191]]
+
* [[PL-59]] 1 cond, chrome finish U/W [[SO-39]] P/O [[CD-141]], [[BC-191]]
 
* [[PL-P59]] S/T PL-59, with conduit bushing
 
* [[PL-P59]] S/T PL-59, with conduit bushing
 
* [[PL-Q59]] S/T PL-59, with rt-angle collar
 
* [[PL-Q59]] S/T PL-59, with rt-angle collar
* [[PL-R59]]     S/T PL-59, 90ø shell, [[FT-137]], [[M-147]], U/W SO-39  P/O CD-210,238,321
+
* [[PL-R59]]     S/T PL-59, 90ø shell, [[FT-137]], [[M-147]], U/W [[SO-39]] P/O [[CD-210]],238,321
 
* [[PL-S59]] S/T PL-59
 
* [[PL-S59]] S/T PL-59
 
* [[PL-60]] 2 cond U/W [[M-143]], S-40
 
* [[PL-60]] 2 cond U/W [[M-143]], S-40
Line 71: Line 105:
 
* [[PL-Q61]] S/T PL-61, rt-angle collar
 
* [[PL-Q61]] S/T PL-61, rt-angle collar
 
* [[PL-S61]] S/T PL-61
 
* [[PL-S61]] S/T PL-61
* [[PL-62]] 6 cond. chrome shell U/W SO-42
+
* [[PL-62]] 6 cond. chrome shell U/W [[SO-42]]
 
* [[PL-P62]] S/T PL-62, with conduit bushing
 
* [[PL-P62]] S/T PL-62, with conduit bushing
 
* [[PL-Q62]] S/T PL-62, rt-angle collar
 
* [[PL-Q62]] S/T PL-62, rt-angle collar
 
* [[PL-R62]] S/T PL-62, rt-angle collar, [[FT-138]] Clamp & [[M-150]] Conn., SO-42
 
* [[PL-R62]] S/T PL-62, rt-angle collar, [[FT-138]] Clamp & [[M-150]] Conn., SO-42
 
* [[PL-S62]] S/T PL-62, [[FT-138]] Clamp & [[M-150]] Conn., SO-42
 
* [[PL-S62]] S/T PL-62, [[FT-138]] Clamp & [[M-150]] Conn., SO-42
* [[PL-63]] 8 cond, U/W SO-43
+
* [[PL-63]] 8 cond, U/W [[SO-43]]
 
* [[PL-P63]] S/T PL-63, with conduit bushing
 
* [[PL-P63]] S/T PL-63, with conduit bushing
 
* [[PL-Q63]] S/T PL-63, rt-angle collar
 
* [[PL-Q63]] S/T PL-63, rt-angle collar
* [[PL-S63]] S/T PL-63, [[FT-138]] & [[M-151]], SO-43 P/O CD-324
+
* [[PL-S63]] S/T PL-63, [[FT-138]] & [[M-151]], [[SO-43]] P/O [[CD-324]]
* [[PL-64]] 8 cond, U/W SO-44, [[BC-191]]
+
* [[PL-64]] 8 cond, U/W [[SO-44]], [[BC-191]]
 
* [[PL-P64]] S/T PL-64, with conduit bushing
 
* [[PL-P64]] S/T PL-64, with conduit bushing
 
* [[PL-Q64]] S/T PL-64, rt-angle collar
 
* [[PL-Q64]] S/T PL-64, rt-angle collar
* [[PL-S64]] S/T PL-64, [[FT-138]], [[M-152]], SO-44
+
* [[PL-S64]] S/T PL-64, [[FT-138]], [[M-152]], [[SO-44]]
* [[PL-65]] 6 cond, chrome finish, U/W [[M-143]], SO-45
+
* [[PL-65]] 6 cond, chrome finish, U/W [[M-143]], [[SO-45]]
 
* [[PL-Q65]] S/T PL-65, rt-angle collar P/O A-1 Marker Beacon
 
* [[PL-Q65]] S/T PL-65, rt-angle collar P/O A-1 Marker Beacon
 
* [[PL-S65]] S/T PL-6
 
* [[PL-S65]] S/T PL-6
* [[PL-67]] 1 cond, U/W SO-47
+
* [[PL-67]] 1 cond, U/W [[SO-47]]
 
* [[PL-Q67]] S/T PL-67, rt-angle collar
 
* [[PL-Q67]] S/T PL-67, rt-angle collar
* [[PL-68]] P-T Mic Plug, 3-cond.  U/W J-670, JK-33*, [[T-13]], [[T-17]], etc.
+
* [[PL-68]] P-T Mic Plug, 3-cond.  U/W [[J-670]], [[JK-33]]*, [[T-13]], [[T-17]], etc.
* [[PL-69]] 6 cond, U/W SO-51 P/O CD-138
+
* [[PL-69]] 6 cond, U/W [[SO-51]] P/O [[CD-138]]
* [[PL-70]] 6-cond, U/W SO-50 P/O CD-138
+
* [[PL-70]] 6-cond, U/W SO-50 P/O [[CD-138]]
* [[PL-71]] 3-cond, U/W SO-38 P/O CD-179,182
+
* [[PL-71]] 3-cond, U/W SO-38 P/O [[CD-179]],182
* [[PL-72]] 5-cond, U/W SO-48 P/O CD-178,212,243
+
* [[PL-72]] 5-cond, U/W SO-48 P/O [[CD-178]],212,243
* [[PL-74]] 4-cond, U/W SO-54 P/O CD-306
+
* [[PL-74]] 4-cond, U/W [[SO-54]] P/O [[CD-306]]
 
* [[PL-P74]] S/T PL-74, with conduit bushing
 
* [[PL-P74]] S/T PL-74, with conduit bushing
 
* [[PL-Q74]] S/T PL-74, rt-angle collar
 
* [[PL-Q74]] S/T PL-74, rt-angle collar
 
* [[PL-S74]] S/T PL-74, [[FT-136]], [[M-155]], SO-54
 
* [[PL-S74]] S/T PL-74, [[FT-136]], [[M-155]], SO-54
 
* [[PL-75]] 7-cond. U/W SO-37
 
* [[PL-75]] 7-cond. U/W SO-37
* [[PL-76]] 2-cond, U/W SO-56 P/O CD-136
+
* [[PL-76]] 2-cond, U/W SO-56 P/O [[CD-136]]
 
* [[PL-P76]] S/T PL-76, with conduit bushing
 
* [[PL-P76]] S/T PL-76, with conduit bushing
 
* [[PL-Q76]] S/T PL-76, rt-angle collar
 
* [[PL-Q76]] S/T PL-76, rt-angle collar
Line 107: Line 141:
 
* [[PL-Q77]] S/T PL-77, rt-angle collar
 
* [[PL-Q77]] S/T PL-77, rt-angle collar
 
* [[PL-R77]] S/T PL-77
 
* [[PL-R77]] S/T PL-77
* [[PL-77-A]] S/T PL-77, not interchangable P/O CD-137-A
+
* [[PL-77-A]] S/T PL-77, not interchangable P/O [[CD-137]]-A
* [[PL-78]] 6-cond, rt-angle, U/W SO-50 P/O CD-163,174,242
+
* [[PL-78]] 6-cond, rt-angle, U/W SO-50 P/O [[CD-163]],174,242
* [[PL-79]] 6-cond, U/W SO-34 P/O CD-189
+
* [[PL-79]] 6-cond, U/W SO-34 P/O [[CD-189]]
* [[PL-80]] 3-cond, U/W SO-38 P/O CD-214
+
* [[PL-80]] 3-cond, U/W SO-38 P/O [[CD-214]]
* [[PL-81]] 5-cond, U/W SO-35 P/O CD-156,181,183,185,208,213
+
* [[PL-81]] 5-cond, U/W SO-35 P/O [[CD-156]],181,183,185,208,213
 
* [[PL-82]] 4-cond. U/W SO-46
 
* [[PL-82]] 4-cond. U/W SO-46
* [[PL-83]] 5-cond, U/W SO-35 P/O CD-181,183,213,246
+
* [[PL-83]] 5-cond, U/W SO-35 P/O [[CD-181]],183,213,246
 
* [[PL-84]] 4-cond. U/W SO-46
 
* [[PL-84]] 4-cond. U/W SO-46
 
* [[PL-85]] 1-cond, U/W SO-65
 
* [[PL-85]] 1-cond, U/W SO-65
 
* [[PL-86]] 2-cond, U/W SO-66
 
* [[PL-86]] 2-cond, U/W SO-66
 
* [[PL-87]] 2-cond, Female, banana type U/W SO-67
 
* [[PL-87]] 2-cond, Female, banana type U/W SO-67
* [[Pl-88]] 3-cond, U/W SO-68 P/O CD-203
+
* [[PL-88]] 3-cond, U/W SO-68 P/O [[CD-203]]
* [[PL-89]] 4-cond, U/W SO-69 P/O CD-211
+
* [[PL-89]] 4-cond, U/W SO-69 P/O [[CD-211]]
 
* [[PL-90]]
 
* [[PL-90]]
 
* [[PL-91]]
 
* [[PL-91]]
Line 126: Line 160:
 
* [[PL-94]]
 
* [[PL-94]]
 
* [[PL-95]]
 
* [[PL-95]]
* [[PL-96]] 5-cond, U/W SO-77 P/O CD-202
+
* [[PL-96]] 5-cond, U/W SO-77 P/O [[CD-202]]
 
* [[PL-97]] 6-cond, Female, banana type U/W SO-77
 
* [[PL-97]] 6-cond, Female, banana type U/W SO-77
 
* [[PL-98]] 8-cond, Female, banana type U/W SO-78
 
* [[PL-98]] 8-cond, Female, banana type U/W SO-78
 
* [[PL-99]] 8-cond, Female R/B PL-159 U/W SO-79
 
* [[PL-99]] 8-cond, Female R/B PL-159 U/W SO-79
  
* [[PL-100]] 8-cond. R/B [[PL-160]]
+
* [[PL-100]] 8-cond. R/B [[PL-160]], (straight) [[BC-223]], [[SCR-245]]
 
* [[PL-101]]
 
* [[PL-101]]
 
* [[PL-102]] 4-cond. U/W SO-82
 
* [[PL-102]] 4-cond. U/W SO-82
* [[PL-103]] 8-cond, U/W SO-83 P/O [[SCR-187]]*
+
* [[PL-103]] 8-cond, U/W SO-83 P/O [[SCR-187]]*
* [[PL-Q103]] 8-cond, rt-angle, U/W SO-83
+
* [[PL-P103]]
 +
* [[PL-Q103]] 8-cond, rt-angle, U/W SO-83 P/O [[FT-154]], [[BC-224]]
 
* [[PL-Q103A]] 8-cond, rt-angle, cable clamp, U/W SO-83
 
* [[PL-Q103A]] 8-cond, rt-angle, cable clamp, U/W SO-83
* [[PL-P104]] 7-cond, U/W SO-84 P/O CD-304
+
* [[PL-P104]] 7-cond, U/W SO-84 P/O [[CD-304]]
 
* [[PL-Q104]] 7-cond, rt-angle U/W SO-84 P/O [[SCR-AH-183]]
 
* [[PL-Q104]] 7-cond, rt-angle U/W SO-84 P/O [[SCR-AH-183]]
 
* [[PL-105]]
 
* [[PL-105]]
* [[PL-106]] 6-cond, U/W SO-86 P/O CD-195, [[T-24]]A, [[TS-11]]
+
* [[PL-106]] 6-cond, U/W [[SO-86]], P/O [[CD-195]], [[T-24]]A, [[TS-11]], [[RM-14]], [[RM-21]]
 
* [[PL-107]] 2-cond, U/W SO-87, GS-8-A, [[I-65]]A P/O [[SCR-242]]* Radio Comp.
 
* [[PL-107]] 2-cond, U/W SO-87, GS-8-A, [[I-65]]A P/O [[SCR-242]]* Radio Comp.
* [[PL-108]] 4-cond, U/W SO-88,92,218, [[BC-310]]*, [[I-65]]*, TM-180*  P/O [[SCR-242]]*
+
* [[PL-108]] 4-cond, U/W SO-88,92,218, [[BC-310]]*, [[I-65]]*, TM-180*  P/O [[SCR-242]]* [[BC-357]]
* [[PL-109]] 5-cond, U/W TM-180* P/O [[SCR-242]]*
+
* [[PL-109]] 5-cond, U/W [[TM-180]]* P/O [[SCR-242]]*
 
* [[PL-110]]* 21-cond, Female, U/W SO-90, [[M-187]], TM-180*, [[BC-310]]/[[SCR-242]]*
 
* [[PL-110]]* 21-cond, Female, U/W SO-90, [[M-187]], TM-180*, [[BC-310]]/[[SCR-242]]*
 
* [[PL-111]](A) 22-cond, U/W SO-91, [[M-187]], TM-180* P/O [[SCR-242]]*
 
* [[PL-111]](A) 22-cond, U/W SO-91, [[M-187]], TM-180* P/O [[SCR-242]]*
* [[PL-112]] 9-cond, U/W SO-92 (S)-212) TM-180* P/O SCR-242*,269*
+
* [[PL-112]] 9-cond, U/W [[SO-92]] (S)-212) TM-180* P/O SCR-242*,269*
* [[PL-113]] 4-cond, U/W SO-93, TM-180* P/O SCR-242*
+
* [[PL-113]] 4-cond, U/W [[SO-93]], [[TM-180]]* P/O [[SCR-242]]*
* [[PL-114]] 14-cond, Female, U/W SO-94 P/O [[BC-312]], [[BC-342]]*, ect. TRA-7
+
* [[PL-114]] 14-cond, Female, U/W [[SO-94]] P/O [[BC-312]], [[BC-342]]*, ect. TRA-7
* [[PL-118]] 5-cond, U/W [[I-65]]*, TM-180* P/O SCR-242*
+
* [[PL-115]], [[SO-45]], marker beacon ?
 +
* [[PL-116]]
 +
* [[PL-117]], [[SO-105]], [[I-65]]
 +
* [[PL-118]] 5-cond, U/W [[I-65]]*, [[TM-180]]* P/O [[SCR-242]]*
 
* [[PL-119]] 2-cond, U/W SO-99, [[BC-310]]* P/O SCR-242*
 
* [[PL-119]] 2-cond, U/W SO-99, [[BC-310]]* P/O SCR-242*
* [[PL-120]] 4-cond, U/W BC-310*, GD-7, GS-8 P/O CD-310
+
* [[PL-120]] 4-cond, U/W [[BC-310]]*, GD-7, GS-8 P/O [[CD-310]]
 
* [[PL-121]] 18-cond, U/W [[BC-311]]*, TM-180* P/O SCR-242*
 
* [[PL-121]] 18-cond, U/W [[BC-311]]*, TM-180* P/O SCR-242*
* [[PL-122]] 22-Cond, U/W SO-102
+
* [[PL-122]] 22-Cond, U/W [[SO-102]]
* [[PL-123]] 2-Cond, U/W TM-180*
+
* [[PL-123]] 2-Cond, U/W [[TM-180]]*
 
* [[PL-124]]
 
* [[PL-124]]
 
* [[PL-125]] 2-cond. Telephone Plug  U/W [[JK-24]],34
 
* [[PL-125]] 2-cond. Telephone Plug  U/W [[JK-24]],34
 
* [[PL-126]]
 
* [[PL-126]]
* [[PL-127]]
+
* [[PL-127]], [[SO-107]],
 
* [[PL-128]]
 
* [[PL-128]]
 
* [[PL-129]]
 
* [[PL-129]]
Line 174: Line 212:
 
* [[PL-141]]
 
* [[PL-141]]
 
* [[PL-142]]
 
* [[PL-142]]
* [[PL-143]] 12-cond. P/O CD-367,368,369
+
* [[PL-143]] 12-cond. P/O [[CD-367]],368,369
* [[PL-144]] 11-cond, S/T PL-64, U/W SO-124 P/O [[RC-30]], 31
+
* [[PL-144]] 11-cond, S/T PL-64, U/W [[SO-124]] P/O [[RC-30]], 31
 
* [[PL-145]] 9-cond, Female, S/T PL-100, U/W [[GR-3]]-C  P/O CD-439,443
 
* [[PL-145]] 9-cond, Female, S/T PL-100, U/W [[GR-3]]-C  P/O CD-439,443
 
* [[PL-146]] 8-cond, U/W SO-78  for GR-3-C P/O CD-438,444
 
* [[PL-146]] 8-cond, U/W SO-78  for GR-3-C P/O CD-438,444
 
* [[PL-147]]  2-pin, part numbers 6578 or 9127 U/W CO-204 [[SCR-274]]N
 
* [[PL-147]]  2-pin, part numbers 6578 or 9127 U/W CO-204 [[SCR-274]]N
 
* [[PL-148]]  3-pin, part numbers 6965 or 9126 U/W CO-204 [[SCR-274]]N
 
* [[PL-148]]  3-pin, part numbers 6965 or 9126 U/W CO-204 [[SCR-274]]N
* [[PL-149]] [[BC-223]], [[SCR-245]]
+
* [[PL-149]] (right angle), [[BC-223]], [[SCR-245]]
* [[PL-150]] [[PE-55]], power cord, to [[BC-223]] [[SCR-245]]
+
* [[PL-150]] (right angle), [[PE-55]], power cord, to [[BC-223]] [[SCR-245]]
 
* [[PL-151]]  6-pin, part numbers 6784 or 9123 U/W CO-205 [[SCR-274]]N
 
* [[PL-151]]  6-pin, part numbers 6784 or 9123 U/W CO-205 [[SCR-274]]N
 
* [[PL-152]]  8-pin, part numbers 6577 or 9125 U/W CO-206 [[SCR-274]]N
 
* [[PL-152]]  8-pin, part numbers 6577 or 9125 U/W CO-206 [[SCR-274]]N
 
* [[PL-153]]  18-pin, part number 6963 or 9121 U/W CO-207, [[RC-96]]A
 
* [[PL-153]]  18-pin, part number 6963 or 9121 U/W CO-207, [[RC-96]]A
 
* [[PL-154]]  12-pin, part number 6964 or 9122 U/W CO-210 [[SCR-274]]N
 
* [[PL-154]]  12-pin, part number 6964 or 9122 U/W CO-210 [[SCR-274]]N
* [[PL-155]]  2-cond, stubbier version of PL-55 U/W JK-34 [[SCR-274]]N
+
* [[PL-155]]  2-cond, stubbier version of PL-55 U/W [[JK-34]] [[SCR-274]]N
 
* [[PL-156]]  5-pin, part numbers 6967 or 9124 U/W CO-205 [[SCR-274]]N
 
* [[PL-156]]  5-pin, part numbers 6967 or 9124 U/W CO-205 [[SCR-274]]N
 
* [[PL-157]]  2-pin, part numbers 3146 or 7543 U/W CO-211  (discontd)
 
* [[PL-157]]  2-pin, part numbers 3146 or 7543 U/W CO-211  (discontd)
 
* [[PL-158]]  2-cond U/W CO-211, SO-99  (discontd)
 
* [[PL-158]]  2-cond U/W CO-211, SO-99  (discontd)
* [[PL-159]]  8-cond, Female R/F PL-99 U/W SO-79
+
* [[PL-159]]  8-cond, (straight), Female R/F PL-99 U/W SO-79
* [[PL-160]]  8-cond, R/F PL-100 U/W SO-80
+
* [[PL-160]]  8-cond, (straight) R/F PL-100 [[BC-223]], [[PE-55]] U/W SO-80
 
* [[PL-161]]  10-cond, Female P/O [[SCR-268]]
 
* [[PL-161]]  10-cond, Female P/O [[SCR-268]]
 
* [[PL-162]]  19-cond, Female
 
* [[PL-162]]  19-cond, Female
Line 212: Line 250:
 
* [[PL-P/Q173]] S/T PL-173
 
* [[PL-P/Q173]] S/T PL-173
 
* [[PL-174]]
 
* [[PL-174]]
* [[PL-175]] 2-cond, Female.  U/W SO-155
+
* [[PL-175]] 2-cond, Female.  U/W [[SO-155]]
 
* [[PL-176]] 1-cond, Female.  P/O [[SCR-535]]*
 
* [[PL-176]] 1-cond, Female.  P/O [[SCR-535]]*
 
* [[PL-177]] 2-cond, Female. P/O SCR-535*, 695*
 
* [[PL-177]] 2-cond, Female. P/O SCR-535*, 695*
* [[PL-178]]
+
* [[PL-178]], 3-conductor, male, [[SO-158]], [[BC-648]]
* [[Pl-179]] 4-cond, U/W JK-49 P/O Mic [[T-34]]-A
+
* [[PL-179]] 4-cond, Male,  [[JK-49]] U/W JK-26 P/O Mic [[T-34]]-A. [[T-44]].
 
* [[PL-180]] 3-cond. P/O [[SCR-535]]*
 
* [[PL-180]] 3-cond. P/O [[SCR-535]]*
 
* [[PL-181]] 5-cond, Male, rcvr-control box P/O SCR-535*
 
* [[PL-181]] 5-cond, Male, rcvr-control box P/O SCR-535*
Line 235: Line 273:
 
* [[PL-196]]
 
* [[PL-196]]
 
* [[PL-197]] AN-3106-9S U/W [[I-100]]-* P/O CD-551
 
* [[PL-197]] AN-3106-9S U/W [[I-100]]-* P/O CD-551
* [[PL-198]]
+
* [[PL-198]], [[RM-26]]
 
* [[PL-199]]* 6-cond, Female, S/T PL-Q166 U/W [[JB-29]]* P/O [[SCR-522]], 542
 
* [[PL-199]]* 6-cond, Female, S/T PL-Q166 U/W [[JB-29]]* P/O [[SCR-522]], 542
 
 
* [[PL-P200]] 5-cond, Female  AN-3106-14S-5S P/O [[SCR-636]]*
 
* [[PL-P200]] 5-cond, Female  AN-3106-14S-5S P/O [[SCR-636]]*
* [[PL-201]] 80-cond, Male, U/W SO-181 P/O [[SCR-561]], 572
+
* [[PL-201]] 80-cond, Male, U/W [[SO-181]] P/O [[SCR-561]], 572
 
* [[PL-202]]
 
* [[PL-202]]
 
* [[PL-203]] 8-cond. P/O [[SCR-585]]
 
* [[PL-203]] 8-cond. P/O [[SCR-585]]
* [[PL-204]] Combined PL-55 & PL-68 U/W JK-51, CC-348  P/O TS-14/, etc.
+
* [[PL-204]] Combined [[PL-55]] & [[PL-68]] U/W [[JK-51]], CC-348  P/O [[TS-14]]/, etc.
* [[Pl-205]] 8-cond, Female, rt-angle, RCA, U/W SO-195  P/O CD-647,750
+
* [[Pl-205]] 8-cond, Female, rt-angle, RCA, U/W [[SO-195]] P/O [[CD-647]],750
 
* [[PL-206]]
 
* [[PL-206]]
 
* [[PL-207]]
 
* [[PL-207]]
Line 299: Line 336:
 
* [[PL-257]]* 4-cond, Female, U/W SO-220 P/O [[RC-103]]*, AN/AMQ-2
 
* [[PL-257]]* 4-cond, Female, U/W SO-220 P/O [[RC-103]]*, AN/AMQ-2
 
* [[PL-258]] UHF dual Female Plug    U/W PL-259
 
* [[PL-258]] UHF dual Female Plug    U/W PL-259
* [[PL-259]]* UHF Male Plug U/W SO-139 U/W RG-7,8,9/U
+
* [[PL-259]]* UHF Male Plug U/W [[SO-139]] U/W RG-7,8,9/U
 
* [[PL-260]]
 
* [[PL-260]]
 
* [[PL-261]]
 
* [[PL-261]]
 
* [[PL-262]]
 
* [[PL-262]]
* [[PL-263]]* 9-cond, AN-3106-28-4S, U/W SO-243 P/O CD-692
+
* [[PL-263]]* 9-cond, AN-3106-28-4S, U/W [[SO-243]] P/O CD-692
 
* [[PL-264]]
 
* [[PL-264]]
 
* [[PL-265]] 5-cond, Female  British 395 P/O [[SCR-695]]*
 
* [[PL-265]] 5-cond, Female  British 395 P/O [[SCR-695]]*
Line 324: Line 361:
 
* [[Pl-282]]
 
* [[Pl-282]]
 
* [[PL-283]]
 
* [[PL-283]]
* [[PL-284]] RF Plug, UG-102/U, U/W UG-103/U, SO-264 & RG-22/U "Twinax" Cable
+
* [[PL-284]] RF Plug, UG-102/U, U/W UG-103/U, [[SO-264]] & RG-22/U "Twinax" Cable
 
* [[PL-285]] RF Plug, UG-105/U, mates with PL-284, UG-102/U
 
* [[PL-285]] RF Plug, UG-105/U, mates with PL-284, UG-102/U
 
* [[PL-286]]
 
* [[PL-286]]
Line 331: Line 368:
 
* [[Pl-289]]
 
* [[Pl-289]]
 
* [[Pl-290]]
 
* [[Pl-290]]
* [[PL-291]]* Microphone Plug, 2-cond.  U/W JK-48,55  P/O [[T-30]]*, and [[T-45]] ANB-MC-1
+
* [[PL-291]]* Microphone Plug, 2-cond.  U/W [[JK-48]],55  P/O [[T-30]]*, and [[T-45]] ANB-MC-1
 
* [[Pl-292]]
 
* [[Pl-292]]
 
* [[PL-293]]
 
* [[PL-293]]
* [[PL-294]] 9-cond, Male, banana pins, U/W SO-141 P/O CD-1086
+
* [[PL-294]] 9-cond, Male, banana pins, U/W [[SO-141]] P/O [[CD-1086]]
* [[PL-295]] Male, 2-cond. U/W SO-265, WC-550
+
* [[PL-295]] Male, 2-cond. U/W [[SO-265]], WC-550
 
* [[Pl-296]]
 
* [[Pl-296]]
 
* [[PL-297]]
 
* [[PL-297]]
Line 343: Line 380:
 
* [[PL-300]] Power Plug, 6-cond. P/O [[SCR-299]]*, 399*
 
* [[PL-300]] Power Plug, 6-cond. P/O [[SCR-299]]*, 399*
 
* [[PL-301]] 7-cond.
 
* [[PL-301]] 7-cond.
* [[PL-302]] 7-cond. P/O CD-722
+
* [[PL-302]] 7-cond. P/O [[CD-722]]
 
* [[Pl-301]]
 
* [[Pl-301]]
 
* [[Pl-302]]
 
* [[Pl-302]]
Line 349: Line 386:
 
* [[PL-304]]
 
* [[PL-304]]
 
* [[PL-305]]
 
* [[PL-305]]
* [[PL-306]] Female Coax U/W AN-56, CD-1082 P/O [[RC-81]]
+
* [[PL-306]] Female Coax U/W [[AN-56]], [[CD-1082]] P/O [[RC-81]]
 
* [[PL-307]]
 
* [[PL-307]]
 
* [[PL-308]] Male Coax P/O CD-1083,1084,1085
 
* [[PL-308]] Male Coax P/O CD-1083,1084,1085
* [[PL-309]] Female Coax, fits SO-153 U/W BC-639  P/O CD-1084
+
* [[PL-309]] Female Coax, fits [[SO-153]] U/W BC-639  P/O CD-1084
 
* [[PL-310]] Male Coax, rt-angle, fits SO-153 P/O CD-1085
 
* [[PL-310]] Male Coax, rt-angle, fits SO-153 P/O CD-1085
 +
 +
  
 
* [[PL-354]] Red Headset Plug, 2-cond, for [[JK-26]]  S/T PL-54 P/O [[HS-33]],38
 
* [[PL-354]] Red Headset Plug, 2-cond, for [[JK-26]]  S/T PL-54 P/O [[HS-33]],38
 
+
* [[PL-500]], power [[CD-500]], [[RA-63]] (Hubble No. 7411)
 
* [[PL-540]] Telephone Plug, two-way   U/W [[RC-169]] P/O [[MC-572]]
 
* [[PL-540]] Telephone Plug, two-way   U/W [[RC-169]] P/O [[MC-572]]
  
 +
==References==
 +
* [[File:Aircraft Plugs and Connectors.pdf]]
  
 
[[Category:Equipment Group]]
 
[[Category:Equipment Group]]

Latest revision as of 16:02, 1 July 2024

notes

On the connectors, writing an explanation that would allow anyone to understand the nomenclature system would take all day and I'd probably miss something anyway. So I'll abbreviate it.


The full nomenclature of most of the large banana pin style cable connectors with the push-button lock (as opposed to an Acme thread nut) is as follows:

  • PL-xnn where "nn" is a 2-digit number and "x" is"
  • P = straight back shell with solder gland
  • Q = right-angle back shell with solder gland
  • R = right angle back shell with cable clamp or straight back shell with right-angle cable clamp
  • S = straight back shell with cable clamp

The PL-103 only came in P and Q. Some other plugs (but not these five) had only PL-nn nomenclature.

For whatever reason, the aircraft installations usually use solder gland types and vehicular installations usually use cable clamps. We don't actually know what they would have used for an aircraft set installed in a vehicle, but I would bet on cable clamp and rubber jacketed cable, which is in any case much easier to either simulate or duplicate. So making that assumption, the actual nomenclature of the connectors that you need to put an SCR-187 into the T-36 are:

PL-S59 x 2, PL-S61 x 2, PL-S64 plus whatever the other end needs, PL-S74 plus whatever the other end needs, and PL-S103 or PL-Q103. If you stack the receiver on top of the transmitter, PL-Q103 will probably work better as on it, the cable drops out the bottom rather than sticking out the back.

That being said, most sellers on eBay or elsewhere won't know all of this and will just refer to them as PL-59, PL-61, etc. You'll have to look at the photos to tell what they are really selling.

Yes, PL is a cable plug. No, PLS doesn't mean anything. The mating chassis connector will have a nomenclature of SO-nn. The plug in the back of the BC-224 is SO-104, despite the fact that it is male.

If you cannot find them closer by, I can supply the PL-S59 through PL-S64 but only with the modified Romex cable clamp. When you make up your mind whether to stack the radios or not and can then decide whether straight or right angle PL-x103 will work best, I am supposed to have one PL-Q103 (if I can locate it) that I would swap even for the PL-P103 you have.

The manual I took the two photos out of does not have one showing cables coming out of the BC-191. I'll try to find one, or take a picture of one of the connectors and post it.

Right now, I have to get back to scanning NAVAER 08-5Q-95 for an order I accepted. I thought I had done the scanning ten years or so ago, didn't, but still have to ship. Gunner USNR Retired MVPA 9480

List

  • PL-1 2-conductor, service buzzer EE-63
  • PL-2 3-conductor, JK-15
  • PL-3 ?
  • PL-4 ?
  • PL-5 Audio Plug U/W JK-14,29,39 P/O P-11, Key J-40, CD-56
  • PL-6 two terminal, WEco. No. 156
  • PL-7 two terminal,
  • PL-8 two terminal, WEco. No. 158 Plug U/W JK-7
  • PL-9 four terminal, WEco. No. 164
  • PL-10 four terminal, WEco. No. 160
  • PL-11, switchboard plug, JK-47, EE-2, SCR-134
  • PL-12 single terminal, WEco. No. 159
  • PL-13 same as PL-8 but without screw eye.
  • PL-14 polarity, 2 single terminal plug bodies, mounted in a bakelight block. fits JK-6.
  • PL-15 four single terminal plug bodies, mounted in two hard rubber blocks, for CD-24 cord, BC-13, WEco. No. 162
  • PL-16 telephone, copy of french type,
  • PL-17, black dilecto block, double spring pins, 4-Volt
  • PL-18, same as 17 except 10-Volt
  • PL-19, same as 17 but marked amplifier
  • PL-20, same as 17 but marked telephone.
  • PL-21, 2 terminal mounted between fiber blocks, EE-14
  • PL-22, 2 conductor, two pin, in hard rubber block, CD-81, and CD-34
  • PL-23, 2 single terminal plug bodies molded in compound. for EE-10
  • PL-24, 1 single terminal in hard rubber sleeve, for BC-92
  • PL-25, metal, plug to close hole in pipe ? P/O EE-20
  • PL-26, solid brass, copper plated, with brass thumbpiece. P/O BD-15
  • PL-27, 2 spring bras contact strips, mounted on micarta base. P/O BE-11
  • PL-28, 2 conductor, No.18 coper strips, GE Co. marine outlet No.22323. for target range ?
  • PL-29, ??
  • PL-30, connecting, telephone, water tight, P/O EE-49 telautograph
  • PL-31, connecting, 7-contact, water tight, EE-49
  • PL-32, 2 single contact plug bodies attached to a black fiber handle, for SW-62

(NOTE 1920 storage catalog ends here)


References